Evaluation of the jacking force in microtunneling technology
author:
ZUZANNA FYALL, LESZEK WYSOCKI
ORCID ID:
0000-0002-3695-6659, 0000-0002-2424-7214
No:
5/2025 Instal pp.31-33
DOI:
10.36119/15.2025.5.4
Every manufacturer of jacking pipes specifies the maximum permissible jacking force, the exceeding of which may
result in damage to the pipes. Therefore, the precise determination of the jacking force during the construction of the
pipe when using microtunneling technology is crucial for the safety of this procedure. The determination of the jacking
force is also necessary to specify the distance between the starting and receiving wells. This distance is of significant
importance for the costs of the construction of the pipe because it determines the number of wells on the pipe’s route.
The cost of building a well may be higher than the cost of building the pipe itself. This paper attempts to both
theoretically estimate the jacking force and verify the obtained results based on the value of the actual force measured
during the construction of a specific sewage pipe.
Keywords:
About Authors:
Mgr inż. Zuzanna Fyall https://orcid.org/0000-0002-3695-6659; e-mail: zuzanna.fyall@pwr.edu.pl, Dr inż. Leszek Wysocki, em. prof. uczelni https://orcid.org/0000-0002-2424-7214; e-mail: leszek.wysocki@pwr.edu.pl ‒ Katedra Mechaniki Budowli i Inżynierii Miejskiej
Politechniki Wrocławskiej