{"id":15538,"date":"2020-09-29T12:23:02","date_gmt":"2020-09-29T10:23:02","guid":{"rendered":"https:\/\/informacjainstal.com.pl\/artykul\/przeglad-zalecen-dla-instalacji-wentylacyjnych-i-klimatyzacyjnych-w-zwiazku-z-zagrozeniem-koronawirusem-sars-cov-2-i-choroba-covid-19\/"},"modified":"2022-11-16T11:50:06","modified_gmt":"2022-11-16T10:50:06","slug":"review-of-recommendations-for-ventilation-and-air-conditioning-systems-in-relation-to-the-sars-cov-2-coronavirus-risk-and-the-covid-19-disease","status":"publish","type":"artykul","link":"https:\/\/informacjainstal.com.pl\/en\/article\/review-of-recommendations-for-ventilation-and-air-conditioning-systems-in-relation-to-the-sars-cov-2-coronavirus-risk-and-the-covid-19-disease\/","title":{"rendered":"Review of recommendations for ventilation and air-conditioning systems in relation to the SARS-CoV-2 coronavirus risk and the COVID-19 disease"},"content":{"rendered":"<!--themify_builder_content-->\n<div id=\"themify_builder_content-15538\" data-postid=\"15538\" class=\"themify_builder_content themify_builder_content-15538 themify_builder tf_clear\">\n                    <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_4xvs286 tb_first tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_4qjb289 first\">\n                    <!-- module buttons -->\n<div  class=\"module module-buttons tb_h0nr510 buttons-horizontal solid  squared\" data-lazy=\"1\">\n        <div class=\"module-buttons-item tf_in_flx\">\n                        <a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2020\/09\/art-3.pdf\" class=\"ui builder_button tf_in_flx themify_lightbox tb_default_color\" >\n                                                Read more                                        <\/a>\n                <\/div>\n            <\/div>\n<!-- \/module buttons -->\n        <\/div>\n                        <\/div>\n        <\/div>\n        <\/div>\n<!--\/themify_builder_content-->","protected":false},"excerpt":{"rendered":"<p>The article presents and analyses recommendations and guidelines of significant industry societies such as ASHRAE,<br \/>\nREHVA, EUROVENT ME and polish National Institute of Public Health (NIZP-PZH) for the reduction of potential risk<br \/>\nof transmission of the SARS-CoV-2 virus and as a result the COVID-19 disease through ventilation installations.<br \/>\nAn attempt has been made to systematize the collected recommendations. They are intended to provide a basis for<br \/>\ndetailed guidelines and procedures for HVAC installations for ad hoc implementation in existing facilities. These<br \/>\nactions may require additional training for technical staff and property managers.<\/p>\n","protected":false},"featured_media":0,"parent":0,"menu_order":0,"template":"","meta":[],"tags":[1741,1738,1740,546],"tematyka":[488],"class_list":["post-15538","artykul","type-artykul","status-publish","hentry","tag-coronavirus","tag-covid-19-en","tag-sars-cov-2-en","tag-ventilation","tematyka-ventilation-air-conditioning-cooling","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author",""],"ptb_metabox":{"ptb_artykul_text_1":["PAWE\u0141 SZA\u0141A\u0143SKI","WOJCIECH CEPI\u0143SKI","JACEK MISI\u0143SKI"],"ptb_artykul_text_2":"10.36119\/15.2020.5.3","ptb_artykul_numer_miesi_cznika":"5\/2020 instal p. 17-21","ptb_artykul_info_autor":"dr in\u017c. Pawe\u0142 Sza\u0142a\u0144ski, https:\/\/orcid\/0000-0001-9263-3486; dr in\u017c. Wojciech Cepi\u0144ski, https:\/\/orcid\/0000-0003-4294-0431;\r\nJacek Misi\u0144ski, https:\/\/orcid\/0000-0002-9038-7469 - Katedra Klimatyzacji, Ogrzewnictwa, Gazownictwa i Ochrony Powietrza, Wydzia\u0142\r\nIn\u017cynierii \u015arodowiska, Politechnika Wroc\u0142awska, ul. C.K. Norwida 4\/6, 50-373 Wroc\u0142aw. Corresponding author: pawel.szalanski@pwr.edu.pl","ptb_artykul_orcid":["0000-0001-9263-3486","0000-0003-4294-0431","0000-0002-9038-7469"]},"ptb_taxonomy":{"post_tag":[{"term_id":1741,"name":"coronavirus","slug":"coronavirus","term_group":0,"term_taxonomy_id":1741,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":1738,"name":"COVID-19","slug":"covid-19-en","term_group":0,"term_taxonomy_id":1738,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":1740,"name":"SARS-CoV-2","slug":"sars-cov-2-en","term_group":0,"term_taxonomy_id":1740,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":546,"name":"ventilation","slug":"ventilation","term_group":0,"term_taxonomy_id":547,"taxonomy":"post_tag","description":"","parent":0,"count":19,"filter":"raw"}],"tematyka":[{"term_id":488,"name":"Ventilation, air conditioning, cooling","slug":"ventilation-air-conditioning-cooling","term_group":0,"term_taxonomy_id":488,"taxonomy":"tematyka","description":"","parent":0,"count":64,"filter":"raw"}]},"ptb_featured_image":null,"builder_content":"<a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2020\/09\/art-3.pdf\" > Read more <\/a>","_links":{"self":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul\/15538","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul"}],"about":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/types\/artykul"}],"wp:attachment":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/media?parent=15538"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tags?post=15538"},{"taxonomy":"tematyka","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tematyka?post=15538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}