{"id":16551,"date":"2021-05-18T12:27:37","date_gmt":"2021-05-18T10:27:37","guid":{"rendered":"https:\/\/informacjainstal.com.pl\/artykul\/wplyw-warunkow-srodowiskowych-i-niezamierzonej-hipotermii-srodoperacyjnej-na-stan-pacjenta\/"},"modified":"2022-11-16T11:40:40","modified_gmt":"2022-11-16T10:40:40","slug":"the-influence-of-environmental-conditions-and-inadvertent-perioperative-hypothermia-on-the-patients-conditionv","status":"publish","type":"artykul","link":"https:\/\/informacjainstal.com.pl\/en\/article\/the-influence-of-environmental-conditions-and-inadvertent-perioperative-hypothermia-on-the-patients-conditionv\/","title":{"rendered":"The influence of environmental conditions and inadvertent perioperative hypothermia on the patient\u2019s condition"},"content":{"rendered":"<!--themify_builder_content-->\n<div id=\"themify_builder_content-16551\" data-postid=\"16551\" class=\"themify_builder_content themify_builder_content-16551 themify_builder tf_clear\">\n                    <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_4xvs286 tb_first tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_4qjb289 first\">\n                    <!-- module buttons -->\n<div  class=\"module module-buttons tb_h0nr510 buttons-horizontal solid  squared\" data-lazy=\"1\">\n        <div class=\"module-buttons-item tf_in_flx\">\n                        <a href=\"\/wp-content\/uploads\/2021\/05\/Charkowska-1.pdf\" class=\"ui builder_button tf_in_flx themify_lightbox tb_default_color\" >\n                                                Read more                                        <\/a>\n                <\/div>\n            <\/div>\n<!-- \/module buttons -->\n        <\/div>\n                        <\/div>\n        <\/div>\n        <\/div>\n<!--\/themify_builder_content-->","protected":false},"excerpt":{"rendered":"<p>Environmental conditions (temperature, humidity, air flow velocity, mean radiation temperature) and individual<br \/>\nfactors (physical activity, clothing insulation) affect the heat exchange between humans and the environment. In<br \/>\nthermal balance conditions, a feeling of thermal comfort appears and the body\u2019s thermoregulatory system works<br \/>\nproperly. In conditions where the thermoregulation mechanism is impaired, a person may be hypothermic or<br \/>\nhyperthermic instead of normothermic. One of these situations (hypothermia) can occur in the operating room.<br \/>\nAnesthesia, surgery and the operating room environment impair the body\u2019s physiological thermoregulatory<br \/>\nmechanisms. Inadvertent perioperative hypothermia, defined as a drop in core body temperature below 36\u00b0 C, is<br \/>\nthe most common complication of perioperative care. The article focuses on the issues related to the occurrence of<br \/>\nhypothermia of the operated patient, referring also to the indoor conditions in the operating room, maintained as<br \/>\na result of the operation of the ventilation and air conditioning system in the operating room.<\/p>\n","protected":false},"featured_media":0,"parent":0,"menu_order":0,"template":"","meta":[],"tags":[1856,1710,2392,2391,2387,2393,2390,2388,2389,546],"tematyka":[488],"class_list":["post-16551","artykul","type-artykul","status-publish","hentry","tag-air-conditioning","tag-air-parameters","tag-comfort","tag-discomfort","tag-hospital","tag-hypothermia","tag-medical-staff","tag-operating-room","tag-patients","tag-ventilation","tematyka-ventilation-air-conditioning-cooling","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author",""],"ptb_metabox":{"ptb_artykul_text_1":["ANNA CHARKOWSKA"],"ptb_artykul_text_2":"10.36119\/15.2021.4.2","ptb_artykul_numer_miesi_cznika":"03\/2021 Instal p. 31-36","ptb_artykul_info_autor":"Dr in\u017c. Anna Charkowska, https:\/\/orcid.org\/0000-0001-6060-9895 \u2013 Zak\u0142ad Klimatyzacji i Ogrzewnictwa, Wydzia\u0142 Instalacji Budowlanych, Hydrotechniki i In\u017cynierii \u015arodowiska, Politechnika Warszawska. Corresponding author:\r\nanna.charkowska@pw.edu.pl","ptb_artykul_orcid":["0000-0001-6060-9895"]},"ptb_taxonomy":{"post_tag":[{"term_id":1856,"name":"air conditioning","slug":"air-conditioning","term_group":0,"term_taxonomy_id":1856,"taxonomy":"post_tag","description":"","parent":0,"count":9,"filter":"raw"},{"term_id":1710,"name":"air parameters","slug":"air-parameters","term_group":0,"term_taxonomy_id":1710,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw"},{"term_id":2392,"name":"comfort","slug":"comfort","term_group":0,"term_taxonomy_id":2392,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2391,"name":"discomfort","slug":"discomfort","term_group":0,"term_taxonomy_id":2391,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2387,"name":"hospital","slug":"hospital","term_group":0,"term_taxonomy_id":2387,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":2393,"name":"hypothermia","slug":"hypothermia","term_group":0,"term_taxonomy_id":2393,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2390,"name":"medical staff","slug":"medical-staff","term_group":0,"term_taxonomy_id":2390,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2388,"name":"operating room","slug":"operating-room","term_group":0,"term_taxonomy_id":2388,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2389,"name":"patients","slug":"patients","term_group":0,"term_taxonomy_id":2389,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":546,"name":"ventilation","slug":"ventilation","term_group":0,"term_taxonomy_id":547,"taxonomy":"post_tag","description":"","parent":0,"count":19,"filter":"raw"}],"tematyka":[{"term_id":488,"name":"Ventilation, air conditioning, cooling","slug":"ventilation-air-conditioning-cooling","term_group":0,"term_taxonomy_id":488,"taxonomy":"tematyka","description":"","parent":0,"count":64,"filter":"raw"}]},"ptb_featured_image":null,"builder_content":"<a href=\"\/wp-content\/uploads\/2021\/05\/Charkowska-1.pdf\" > Read more <\/a>","_links":{"self":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul\/16551","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul"}],"about":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/types\/artykul"}],"wp:attachment":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/media?parent=16551"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tags?post=16551"},{"taxonomy":"tematyka","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tematyka?post=16551"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}