{"id":17825,"date":"2022-04-14T13:35:03","date_gmt":"2022-04-14T11:35:03","guid":{"rendered":"https:\/\/informacjainstal.com.pl\/artykul\/ocena-kosztow-renowacji-rurociagow-sieci-wodociagowych-metodami-utwardzonego-rekawa-cipp-i-wykladziny-cementowej\/"},"modified":"2022-11-16T11:27:38","modified_gmt":"2022-11-16T10:27:38","slug":"assessment-of-water-supply-pipe-lines-renovation-costs-using-the-hardened-cipp-sleeve-and-cement-lining-methods","status":"publish","type":"artykul","link":"https:\/\/informacjainstal.com.pl\/en\/article\/assessment-of-water-supply-pipe-lines-renovation-costs-using-the-hardened-cipp-sleeve-and-cement-lining-methods\/","title":{"rendered":"Assessment of water supply pipe lines renovation costs using the hardened CIPP sleeve and cement lining methods"},"content":{"rendered":"<!--themify_builder_content-->\n<div id=\"themify_builder_content-17825\" data-postid=\"17825\" class=\"themify_builder_content themify_builder_content-17825 themify_builder tf_clear\">\n                    <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_7o73471 tb_first tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_16t0471 first\">\n                    <!-- module buttons -->\n<div  class=\"module module-buttons tb_yzs5472 buttons-horizontal solid  squared\" data-lazy=\"1\">\n        <div class=\"module-buttons-item tf_in_flx\">\n                        <a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2022\/04\/Piechurski.pdf\" class=\"ui builder_button tf_in_flx themify_lightbox tb_default_color\" >\n                                                Read more                                        <\/a>\n                <\/div>\n            <\/div>\n<!-- \/module buttons -->\n        <\/div>\n                        <\/div>\n        <\/div>\n        <\/div>\n<!--\/themify_builder_content-->","protected":false},"excerpt":{"rendered":"<p>The operational problems of steel and gray cast iron trunk pipelines become more and more difficult over their<br \/>\noperation time due to insight into corrosion and incrustation. The companies operating them are faced with the<br \/>\nchoice of building new ones or administering existing renovations. On the example of 3 different completed<br \/>\ninvestments of different diameters pipelines, pipelines, the cost of their renovation was assessed.<br \/>\nRenovation 1 is \u00d8500 and \u00d8 800 pipelines, renovation 2 is \u00d8200 to \u00d8 400 pipelines, renovation 3 is \u00d8300 and<br \/>\n\u00d8 450 pipelines. Renovation technologies used were throwing cement and using Seartex-Liner H2O and Phoenix<br \/>\nDouble Jacket sleeves. The prices for the renovation of 1 meter of the gray cast iron pipeline DN800 and DN500<br \/>\nusing the CIPP UV sleeve (Seartex-Liner H2O) were 1760 PLN and 1100 PLN. The price for the renovation of<br \/>\n1 meter of the DN500 steel pipeline using the Phoenix Double Jacket process was 975 PLN. The price for the<br \/>\nrenovation of 1 meter of steel pipeline DN600 using the cement lining process was 412,96 PLN. Therefore,<br \/>\ncomparable investment implementation costs can be incurred using the CIPP UV (Seartex-Liner H2O) and Phoenix<br \/>\nDouble Jacket Process methods. It should be emphasized that the hydraulic properties of the given pipeline<br \/>\nrenovations have been improved<\/p>\n","protected":false},"featured_media":0,"parent":0,"menu_order":0,"template":"","meta":[],"tags":[2922,2918,2916,2925,2924,2923,666],"tematyka":[387],"class_list":["post-17825","artykul","type-artykul","status-publish","hentry","tag-cement-lining-method","tag-koszty-renowacji-rur-en","tag-metoda-rekawa","tag-pipe-renovation-costs","tag-repair-renovation","tag-sleeve-method","tag-water-supply-networks","tematyka-water-supply-and-sewage-system","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author",""],"ptb_metabox":{"ptb_artykul_text_1":["KRZYSZTOF P\u0141OSKI","FLORIAN PIECHURSKI"],"ptb_artykul_text_2":"DOI 10.36119\/15.2022.3.6","ptb_artykul_numer_miesi_cznika":"03\/2022 Instal p. 35-43","ptb_artykul_info_autor":"mgr in\u017c. Krzysztof P\u0142oski, dr in\u017c. Florian Piechurski https:\/\/orcid.org\/\/0000-0001-8065-962X \u2013 Politechnika \u015al\u0105ska Gliwice,\r\nWydzia\u0142 In\u017cynierii \u015arodowiska i Energetyki, Katedra In\u017cynierii Wody \u015aciek\u00f3w. Corresponding author: Florian.Piechurski@polsl.pl","ptb_artykul_orcid":["0000-0001-8065-962"]},"ptb_taxonomy":{"post_tag":[{"term_id":2922,"name":"cement lining method","slug":"cement-lining-method","term_group":0,"term_taxonomy_id":2922,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":2918,"name":"koszty renowacji rur","slug":"koszty-renowacji-rur-en","term_group":0,"term_taxonomy_id":2918,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2916,"name":"metoda r\u0119kawa","slug":"metoda-rekawa","term_group":0,"term_taxonomy_id":2916,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":2925,"name":"pipe renovation costs","slug":"pipe-renovation-costs","term_group":0,"term_taxonomy_id":2925,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":2924,"name":"repair \u2013 renovation","slug":"repair-renovation","term_group":0,"term_taxonomy_id":2924,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":2923,"name":"sleeve method","slug":"sleeve-method","term_group":0,"term_taxonomy_id":2923,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":666,"name":"water supply networks","slug":"water-supply-networks","term_group":0,"term_taxonomy_id":666,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw"}],"tematyka":[{"term_id":387,"name":"Water supply and sewage system","slug":"water-supply-and-sewage-system","term_group":0,"term_taxonomy_id":387,"taxonomy":"tematyka","description":"","parent":0,"count":206,"filter":"raw"}]},"ptb_featured_image":null,"builder_content":"<a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2022\/04\/Piechurski.pdf\" > Read more <\/a>","_links":{"self":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul\/17825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul"}],"about":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/types\/artykul"}],"wp:attachment":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/media?parent=17825"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tags?post=17825"},{"taxonomy":"tematyka","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tematyka?post=17825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}