{"id":19015,"date":"2022-12-21T12:05:55","date_gmt":"2022-12-21T11:05:55","guid":{"rendered":"https:\/\/informacjainstal.com.pl\/artykul\/organizacja-wymiany-powietrza-w-pomieszczeniach-bytowych-w-czasach-zarazy\/"},"modified":"2023-01-10T10:48:23","modified_gmt":"2023-01-10T09:48:23","slug":"air-distribution-system-in-rooms-in-the-time-of-the-plague","status":"publish","type":"artykul","link":"https:\/\/informacjainstal.com.pl\/en\/article\/air-distribution-system-in-rooms-in-the-time-of-the-plague\/","title":{"rendered":"Air distribution system in rooms in the time of the plague"},"content":{"rendered":"<p><\/p>\n\n\n\n<p><\/p>\n\n<!--themify_builder_content-->\n<div id=\"themify_builder_content-19015\" data-postid=\"19015\" class=\"themify_builder_content themify_builder_content-19015 themify_builder tf_clear\">\n                    <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_9gaq329 tb_first tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_nojx329 first\">\n                    <!-- module buttons -->\n<div  class=\"module module-buttons tb_qttt329 buttons-horizontal solid  squared\" data-lazy=\"1\">\n        <div class=\"module-buttons-item tf_in_flx\">\n                        <a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2022\/12\/06.pdf\" class=\"ui builder_button tf_in_flx themify_lightbox tb_default_color\" >\n                                                Read more                                        <\/a>\n                <\/div>\n            <\/div>\n<!-- \/module buttons -->\n        <\/div>\n                        <\/div>\n        <\/div>\n        <\/div>\n<!--\/themify_builder_content-->","protected":false},"excerpt":{"rendered":"<p>The article indicates factors that increase and decrease the risk of airborne transmission of the pathogen in the<br \/>\nroom, using the SARS-CoV-2 experience as an example. In particular, the influence of the organization of air<br \/>\nexchange in rooms on the risk of pathogen transmission was discussed, in dangerous situations \u2013 the presence of<br \/>\na sick person who may be a potential source of infection. Commonly used systems of organization of air exchange<br \/>\nin rooms were analysed in terms of the possibility of the spread of contaminants or pathogens and their effective<br \/>\nremoval or elimination. The influence of devices such as air conditioners, portable fans and air purifiers was also<br \/>\nconsidered. The most favourable solutions were identified, in line with the new paradigm of designing safe installations resulting from the coronavirus pandemic.<\/p>\n","protected":false},"featured_media":0,"parent":0,"menu_order":0,"template":"","meta":[],"tags":[1741,1738,1808,1740,546],"tematyka":[488],"class_list":["post-19015","artykul","type-artykul","status-publish","hentry","tag-coronavirus","tag-covid-19-en","tag-hvac-en","tag-sars-cov-2-en","tag-ventilation","tematyka-ventilation-air-conditioning-cooling","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author",""],"ptb_metabox":{"ptb_artykul_text_1":["WOJCIECH CEPI\u0143SKI","PAWE\u0141 SZA\u0141A\u0143SKI","JACEK MISI\u0143SKI"],"ptb_artykul_text_2":"DOI 10.36119\/15.2022.12.6","ptb_artykul_numer_miesi_cznika":"12\/2022 Instal p. 33-40","ptb_artykul_info_autor":"dr in\u017c.Wojciech Cepi\u0144ski https:\/\/orcid.org\/0000-0003-4294-0431; dr in\u017c. Pawe\u0142 Sza\u0142a\u0144ski https:\/\/orcid.org\/0000-0001-9263-3486; dr in\u017c. Jacek Misi\u0144ski https:\/\/orcid.org\/0000-0002-9038-7469 \u2013 Katedra Klimatyzacji, Ogrzewnictwa, Gazownictwa i Ochrony Powietrza, Wydzia\u0142 In\u017cynierii \u015arodowiska, Politechnika Wroc\u0142awska, Wroc\u0142aw. Corresponding autho: pawel.szalanski@pwr.edu.pl","ptb_artykul_orcid":["0000-0003-4294-0431","0000-0001-9263-3486","0000-0002-9038-7469"]},"ptb_taxonomy":{"post_tag":[{"term_id":1741,"name":"coronavirus","slug":"coronavirus","term_group":0,"term_taxonomy_id":1741,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":1738,"name":"COVID-19","slug":"covid-19-en","term_group":0,"term_taxonomy_id":1738,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":1808,"name":"HVAC","slug":"hvac-en","term_group":0,"term_taxonomy_id":1808,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":1740,"name":"SARS-CoV-2","slug":"sars-cov-2-en","term_group":0,"term_taxonomy_id":1740,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":546,"name":"ventilation","slug":"ventilation","term_group":0,"term_taxonomy_id":547,"taxonomy":"post_tag","description":"","parent":0,"count":19,"filter":"raw"}],"tematyka":[{"term_id":488,"name":"Ventilation, air conditioning, cooling","slug":"ventilation-air-conditioning-cooling","term_group":0,"term_taxonomy_id":488,"taxonomy":"tematyka","description":"","parent":0,"count":64,"filter":"raw"}]},"ptb_featured_image":null,"builder_content":"<a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2022\/12\/06.pdf\" > Read more <\/a>","_links":{"self":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul\/19015","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul"}],"about":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/types\/artykul"}],"wp:attachment":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/media?parent=19015"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tags?post=19015"},{"taxonomy":"tematyka","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tematyka?post=19015"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}