{"id":19146,"date":"2023-01-30T10:45:34","date_gmt":"2023-01-30T09:45:34","guid":{"rendered":"https:\/\/informacjainstal.com.pl\/artykul\/ocena-skutecznosci-roznych-typow-urzadzen-przeznaczonych-do-oczyszczania-powietrza-w-zakresie-redukcji-bakterii-i-grzybow-w-powietrzu-wewnetrznym-w-warunkach-rzeczywistych\/"},"modified":"2023-01-30T10:51:26","modified_gmt":"2023-01-30T09:51:26","slug":"evaluation-of-the-efficiency-of-different-types-of-air-purification-devices-in-scope-of-reducing-the-total-number-of-bacteria-and-fungi-in-indoor-air-in-real-conditions","status":"publish","type":"artykul","link":"https:\/\/informacjainstal.com.pl\/en\/article\/evaluation-of-the-efficiency-of-different-types-of-air-purification-devices-in-scope-of-reducing-the-total-number-of-bacteria-and-fungi-in-indoor-air-in-real-conditions\/","title":{"rendered":"Evaluation of the efficiency of different types of air purification devices in scope of reducing the total number of bacteria and fungi in indoor air in real conditions"},"content":{"rendered":"<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n<!--themify_builder_content-->\n<div id=\"themify_builder_content-19146\" data-postid=\"19146\" class=\"themify_builder_content themify_builder_content-19146 themify_builder tf_clear\">\n                    <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_76ti661 tb_first tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_d8c5662 first\">\n                    <!-- module buttons -->\n<div  class=\"module module-buttons tb_majc662 buttons-horizontal solid  squared\" data-lazy=\"1\">\n        <div class=\"module-buttons-item tf_in_flx\">\n                        <a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2023\/01\/03.pdf\" class=\"ui builder_button tf_in_flx themify_lightbox tb_default_color\" >\n                                                Read more                                        <\/a>\n                <\/div>\n            <\/div>\n<!-- \/module buttons -->\n        <\/div>\n                        <\/div>\n        <\/div>\n        <\/div>\n<!--\/themify_builder_content-->","protected":false},"excerpt":{"rendered":"<p>This article presents results of research on the effectiveness of three types of air purification devices in scope of reducing the total number of bacteria and the total number of fungi. The tested devices used the following purification technologies: Device A &#8211; cold plasma generator and mechanical air filtration, Device B &#8211; multi-stage mechanical filtration and photocatalysis process, Device C &#8211; UV-C flow lamp with carbon filter. The total number of bacteria and fungi in air samples was determined using impact method. The measurements were performed before the devices started to work, during air purification and after the end of the process. The analyzes were carried out in real conditions: one device was used in a pre-Intensive Care Unit room at the Accident and Emergency hospital department, the two others were tested in office rooms. Obtained results show, that the effectiveness of air purifiers in reduction of the total number of bacteria and fungi tested in real conditions was lower than the effectiveness declared by purifier manufacturers. The use of air purifiers to improve indoors air microbiological quality should always be preceded by the appropriate selection of the device. It should take into account the parameters of the target room and the number of people staying in it.<\/p>\n","protected":false},"featured_media":0,"parent":0,"menu_order":0,"template":"","meta":[],"tags":[3542,3540,3541,3543,3544],"tematyka":[488],"class_list":["post-19146","artykul","type-artykul","status-publish","hentry","tag-air-purifiers","tag-airborne-bacteria","tag-airborne-fungi","tag-indoor-air","tag-microbial-air-contamination","tematyka-ventilation-air-conditioning-cooling","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author",""],"ptb_metabox":{"ptb_artykul_text_1":["MACIEJ SZCZOTKO","IZABELA ORYCH","\u0141UKASZ M\u0104KA","JOLANTA SOLECKA"],"ptb_artykul_text_2":"DOI 10.36119\/15.2023.1.3","ptb_artykul_numer_miesi_cznika":"01\/2023 Instal p. 18-26","ptb_artykul_info_autor":"dr Maciej Szczotko, https:\/\/orcid.org\/0000-0001-7740-5768; mgr Izabela Orych, https:\/\/orcid.org\/0000-0003-3693-0923; dr \u0141ukasz M\u0105ka, https:\/\/orcid.org\/0000-0001-6392-9747; dr hab. Jolanta Solecka prof. NIZP PZH - PIB, https:\/\/orcid.org\/0000-0002-6052-3423 \u2013 Narodowy Instytut Zdrowia Publicznego PZH \u2013 Pa\u0144stwowy Instytut Badawczy Zak\u0142ad Bezpiecze\u0144stwa Zdrowotnego \u015arodowiska. Corresponding author: mszczotko@pzh.gov.pl.","ptb_artykul_orcid":["0000-0001-7740-5768","0000-0003-3693-0923","0000-0001-6392-9747","0000-0002-6052-3423"]},"ptb_taxonomy":{"post_tag":[{"term_id":3542,"name":"air purifiers","slug":"air-purifiers","term_group":0,"term_taxonomy_id":3542,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3540,"name":"airborne bacteria","slug":"airborne-bacteria","term_group":0,"term_taxonomy_id":3540,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":3541,"name":"airborne fungi","slug":"airborne-fungi","term_group":0,"term_taxonomy_id":3541,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":3543,"name":"indoor air","slug":"indoor-air","term_group":0,"term_taxonomy_id":3543,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw"},{"term_id":3544,"name":"microbial air contamination","slug":"microbial-air-contamination","term_group":0,"term_taxonomy_id":3544,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"tematyka":[{"term_id":488,"name":"Ventilation, air conditioning, cooling","slug":"ventilation-air-conditioning-cooling","term_group":0,"term_taxonomy_id":488,"taxonomy":"tematyka","description":"","parent":0,"count":64,"filter":"raw"}]},"ptb_featured_image":null,"builder_content":"<a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2023\/01\/03.pdf\" > Read more <\/a>","_links":{"self":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul\/19146","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul"}],"about":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/types\/artykul"}],"wp:attachment":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/media?parent=19146"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tags?post=19146"},{"taxonomy":"tematyka","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tematyka?post=19146"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}