{"id":19397,"date":"2023-03-27T12:40:05","date_gmt":"2023-03-27T10:40:05","guid":{"rendered":"https:\/\/informacjainstal.com.pl\/artykul\/aspekty-techniczne-geologiczne-i-formalno-prawne-pozyskiwania-wod-termalnych\/"},"modified":"2023-03-27T12:43:50","modified_gmt":"2023-03-27T10:43:50","slug":"technical-geological-and-formal-legal-aspects-of-thermal-water-extraction","status":"publish","type":"artykul","link":"https:\/\/informacjainstal.com.pl\/en\/article\/technical-geological-and-formal-legal-aspects-of-thermal-water-extraction\/","title":{"rendered":"Technical, geological and formal-legal aspects of thermal water extraction"},"content":{"rendered":"<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n<!--themify_builder_content-->\n<div id=\"themify_builder_content-19397\" data-postid=\"19397\" class=\"themify_builder_content themify_builder_content-19397 themify_builder tf_clear\">\n                    <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_mzy7882 tb_first tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_xt9e883 first\">\n                    <!-- module buttons -->\n<div  class=\"module module-buttons tb_b9n4883 buttons-horizontal solid  squared\" data-lazy=\"1\">\n        <div class=\"module-buttons-item tf_in_flx\">\n                        <a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2023\/03\/NOGA.pdf\" class=\"ui builder_button tf_in_flx themify_lightbox tb_default_color\" >\n                                                Read more                                        <\/a>\n                <\/div>\n            <\/div>\n<!-- \/module buttons -->\n        <\/div>\n                        <\/div>\n        <\/div>\n        <\/div>\n<!--\/themify_builder_content-->","protected":false},"excerpt":{"rendered":"<p>The article presents technical aspects of thermal water exploitation by discussing geothermal borehole construction.<br \/>\nA one-hole and two-hole system of thermal water exploitation was characterized. Schemes were developed for the<br \/>\npossibility of obtaining geothermal heat depending on the temperature of the extracted thermal water, its cooling<br \/>\ntemperature and the amount of thermal water flowing through the heat exchanger. Geological aspects conditioning the<br \/>\nlocation of geothermal heat plants planned for construction were also analyzed. A list of necessary documents to be<br \/>\nobtained for the exploitation of thermal water was also presented. Finally, the possibilities of financing the geothermal projects planned from the National Fund for Environmental Protection and Water Management were presented.<\/p>\n","protected":false},"featured_media":0,"parent":0,"menu_order":0,"template":"","meta":[],"tags":[3596,3595,3598,3597],"tematyka":[424],"class_list":["post-19397","artykul","type-artykul","status-publish","hentry","tag-geothermal","tag-geothermal-borehole","tag-geothermal-heat","tag-geothermal-installation","tematyka-sources-of-heat-and-electricity","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author",""],"ptb_metabox":{"ptb_artykul_text_1":["BOGDAN NOGA"],"ptb_artykul_text_2":"DOI 10.36119\/15.2023.2.3","ptb_artykul_numer_miesi_cznika":"02\/2023 Instal p. 20-26","ptb_artykul_info_autor":"dr in\u017c. Bogdan Noga https:\/\/orcid.org\/0000-0002-6616-4935 \u2013 Katedra Mechaniki Stosowanej i Mechatroniki, Wydzia\u0142 Mechaniczny, Uniwersytet Technologiczno-Humanistyczny im. K. Pu\u0142askiego w Radomiu, Radom. Corresponding author: b.noga@uthrad.p","ptb_artykul_orcid":["\/0000-0002-6616-4935"]},"ptb_taxonomy":{"post_tag":[{"term_id":3596,"name":"geothermal","slug":"geothermal","term_group":0,"term_taxonomy_id":3595,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw"},{"term_id":3595,"name":"geothermal borehole","slug":"geothermal-borehole","term_group":0,"term_taxonomy_id":3596,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":3598,"name":"geothermal heat","slug":"geothermal-heat","term_group":0,"term_taxonomy_id":3598,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw"},{"term_id":3597,"name":"geothermal installation","slug":"geothermal-installation","term_group":0,"term_taxonomy_id":3597,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw"}],"tematyka":[{"term_id":424,"name":"Sources of heat and electricity","slug":"sources-of-heat-and-electricity","term_group":0,"term_taxonomy_id":424,"taxonomy":"tematyka","description":"","parent":0,"count":120,"filter":"raw"}]},"ptb_featured_image":null,"builder_content":"<a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2023\/03\/NOGA.pdf\" > Read more <\/a>","_links":{"self":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul\/19397","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul"}],"about":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/types\/artykul"}],"wp:attachment":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/media?parent=19397"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tags?post=19397"},{"taxonomy":"tematyka","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tematyka?post=19397"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}