{"id":19477,"date":"2023-04-13T14:47:30","date_gmt":"2023-04-13T12:47:30","guid":{"rendered":"https:\/\/informacjainstal.com.pl\/artykul\/opracowanie-metody-dokladnego-wyznaczania-aktywnosci-wkladow-katalitycznych-oraz-budowa-digital-twin-do-predykcji-zuzycia-katalizatorow-denox\/"},"modified":"2023-04-18T14:01:27","modified_gmt":"2023-04-18T12:01:27","slug":"development-of-a-method-for-precise-determination-of-catalyst-activity-and-construction-of-digital-twin-for-prediction-of-denox-catalyst-deactivation","status":"publish","type":"artykul","link":"https:\/\/informacjainstal.com.pl\/en\/article\/development-of-a-method-for-precise-determination-of-catalyst-activity-and-construction-of-digital-twin-for-prediction-of-denox-catalyst-deactivation\/","title":{"rendered":"Development of a method for precise determination of catalyst activity and construction of Digital-Twin for prediction of deNOx catalyst deactivation"},"content":{"rendered":"<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n<!--themify_builder_content-->\n<div id=\"themify_builder_content-19477\" data-postid=\"19477\" class=\"themify_builder_content themify_builder_content-19477 themify_builder tf_clear\">\n                    <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_72lx21 tb_first tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_pe0q21 first\">\n                    <!-- module buttons -->\n<div  class=\"module module-buttons tb_f9sf21 buttons-horizontal solid  squared\" data-lazy=\"1\">\n        <div class=\"module-buttons-item tf_in_flx\">\n                        <a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2023\/04\/3-Hercog.pdf\" class=\"ui builder_button tf_in_flx themify_lightbox tb_default_color\" >\n                                                Read more                                        <\/a>\n                <\/div>\n            <\/div>\n<!-- \/module buttons -->\n        <\/div>\n                        <\/div>\n        <\/div>\n        <\/div>\n<!--\/themify_builder_content-->","protected":false},"excerpt":{"rendered":"<p>The aim of the work was to develop a fast method of measuring the activity of the entire catalytic layer, a precise method of determining the lifetime (deactivation characteristics) of the catalyst and the construction of an SCR reactor computer tool (based on the so-called \u201cDigital Twin\u201d and machine learning) for determining the lifetime of deNOx catalysts depending on the history of their use and expected further operating conditions.<br \/>\nIn the first stages of work, a preliminary model of the SCR reactor was built, in which the scope and influence of the catalyst operating parameters on its deactivation was determined. For this purpose, the deactivation mechanisms described in the literature were used, as well as the results of experiments and laboratory tests. In addition,<br \/>\na sensitivity analysis was performed to define the most relevant factors influencing catalyst deactivation.<br \/>\nThen, the methodology of measuring the activity of the catalytic layer in-situ was developed, the necessary measurement system was prepared, and comparative tests of catalyst samples were carried out on a laboratory stand and on a block boiler facility at the Siekierki CHP Plant. The SCR-DT software was developed, installed and launched on a server installed in the local network of PGNIG TERMIKA SA. The SCR-DT application accesses operational data on the operating conditions of catalytic layers from the JSMPT server in real time and can import data from xls files available on the local network (e.g. coal, ash and catalyst test data).<br \/>\nApplication of the SCR-DT software makes it possible to reduce the operating costs of catalysts through better maintenance management, extending the periods for their regeneration\/replacement and reducing the amount of waste, thanks to the accurate prediction of their deactivation time and the development of recommendations for their optimal operation.<\/p>\n","protected":false},"featured_media":0,"parent":0,"menu_order":0,"template":"","meta":[],"tags":[3635,3634,3636,3633],"tematyka":[424],"class_list":["post-19477","artykul","type-artykul","status-publish","hentry","tag-catalytic-layer-activity","tag-denox-catalyst-life","tag-digital-twin-2","tag-scr-reactor","tematyka-sources-of-heat-and-electricity","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author",""],"ptb_metabox":{"ptb_artykul_text_1":["JAROS\u0141AW HERCOG","ALEKSANDRA KIEDRZY\u0143SKA","MIROS\u0141AW MALINOWSKI","PAWE\u0141 SA\u0141EK","MARZENA GURGUL","ALEKSANDRA MIKULSKA","DARIUSZ LENKIEWICZ","PAWE\u0141 KOWALCZYK","ALEKSY BARTOSZEWICZ","JACEK OG\u0141Y","JAROS\u0141AW LEDWOCH"],"ptb_artykul_text_2":"DOI 10.36119\/15.2023.3.1","ptb_artykul_numer_miesi_cznika":"03\/2023 Instal p.10-15","ptb_artykul_info_autor":"dr in\u017c. Jaros\u0142aw Hercog (https:\/\/orcid.org\/0000-0003-4891-4592), dr in\u017c. Aleksandra Kiedrzy\u0144ska (https:\/\/orcid.org\/0000-0002-9508- 6163), mgr in\u017c. Miros\u0142aw Malinowski (https:\/\/orcid.org\/0000-0002-9823-2429) \u2013 Instytut Energetyki \u2013 Instytut Badawczy, Zak\u0142ad Proces\u00f3w Cieplnych, Warszawa in\u017c. Pawe\u0142 Sa\u0142ek \u2013 MultizoneIT sp. z o.o., Warszawa mgr in\u017c. Marzena Gurgul, mgr in\u017c. Aleksandra Mikulska (https:\/\/orcid.org\/0000-0002-9976-4750), dr in\u017c. Dariusz Lenkiewicz, mgr in\u017c. Pawe\u0142 Kowalczyk, mgr in\u017c. Aleksy Bartoszewicz, Jacek Og\u0142y, mgr in\u017c. Jaros\u0142aw Ledwoch \u2013 PGNiG TERMIKA SA, Warszawa Corresponding author: miroslaw.malinowski@ien.com.pl","ptb_artykul_orcid":["0000-0001-5737-5143","0000-0002-9164-528X"]},"ptb_taxonomy":{"post_tag":[{"term_id":3635,"name":"catalytic layer activity","slug":"catalytic-layer-activity","term_group":0,"term_taxonomy_id":3635,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3634,"name":"deNOx catalyst life","slug":"denox-catalyst-life","term_group":0,"term_taxonomy_id":3634,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3636,"name":"Digital Twin.","slug":"digital-twin-2","term_group":0,"term_taxonomy_id":3636,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3633,"name":"SCR reactor","slug":"scr-reactor","term_group":0,"term_taxonomy_id":3633,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"tematyka":[{"term_id":424,"name":"Sources of heat and electricity","slug":"sources-of-heat-and-electricity","term_group":0,"term_taxonomy_id":424,"taxonomy":"tematyka","description":"","parent":0,"count":120,"filter":"raw"}]},"ptb_featured_image":null,"builder_content":"<a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2023\/04\/3-Hercog.pdf\" > Read more <\/a>","_links":{"self":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul\/19477","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul"}],"about":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/types\/artykul"}],"wp:attachment":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/media?parent=19477"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tags?post=19477"},{"taxonomy":"tematyka","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tematyka?post=19477"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}