{"id":6547,"date":"2019-12-11T13:50:08","date_gmt":"2019-12-11T12:50:08","guid":{"rendered":"https:\/\/informacjainstal.com.pl\/artykul\/nowoczesne-instalacje-w-obiekcie-o-niskim-zuzyciu-energii-przyklad-najwiekszego-w-polsce-budynku-w-standardzie-nzeb\/"},"modified":"2022-11-16T12:26:52","modified_gmt":"2022-11-16T11:26:52","slug":"modern-installations-in-a-building-with-low-energy-use-the-example-of-the-largest-building-in-poland-in-nzeb-standard","status":"publish","type":"artykul","link":"https:\/\/informacjainstal.com.pl\/en\/article\/modern-installations-in-a-building-with-low-energy-use-the-example-of-the-largest-building-in-poland-in-nzeb-standard\/","title":{"rendered":"Modern installations in a building with low energy use The example of the largest building in Poland in NZEB standard"},"content":{"rendered":"<!--themify_builder_content-->\n<div id=\"themify_builder_content-6547\" data-postid=\"6547\" class=\"themify_builder_content themify_builder_content-6547 themify_builder tf_clear\">\n                    <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_plso402 tb_first tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_5mt2403 first\">\n                    <!-- module text -->\n<div  class=\"module module-text tb_p0ij477   \" data-lazy=\"1\">\n        <div  class=\"tb_text_wrap\">\n        <p><strong>Wprowadzenie <\/strong><\/p><p style=\"text-align: justify;\">Aby wesprze\u0107 realizacj\u0119 globalnego planu dzia\u0142a\u0144 w obszarze klimatu, UE zaproponowa\u0142a nowe cele na 2030 r. [1] w ramach podejmowanych wysi\u0142k\u00f3w na rzecz przej\u015bcia na gospodark\u0119 niskoemisyjn\u0105 i ograniczenia emisji gaz\u00f3w cieplarnianych o 80\u201395% w perspektywie do 2050 r. \u015arodkiem do osi\u0105gni\u0119cia tego zamierzenia jest mi\u0119dzy innymi dekarbonizacja zasob\u00f3w budowlanych. W por\u00f3wnaniu do innych sektor\u00f3w budownictwo jest uznawane za ten obszar, w kt\u00f3rym osi\u0105gni\u0119cie tego ambitnego celu uwa\u017cane jest za stosunkowo \u0142atwe do zrealizowania. Jednak mimo pierwszych znacz\u0105cych sukces\u00f3w budownictwo w UE jest nadal jeszcze dalekie od osi\u0105gni\u0119cia neutralnego dla \u015brodowiska bilansu emisji dwutlenku w\u0119gla. Wiadomym jest, \u017ce spos\u00f3b w jaki budujemy i modernizujemy w chwili obecnej nasze budynki b\u0119dzie mia\u0142 wp\u0142yw na ich emisje nie tylko w tej ale i przysz\u0142ej po\u0142owie XXI wieku ze wzgl\u0119du na stosunkowo du\u017c\u0105 trwa\u0142o\u015b\u0107 substancji budowlanej i jej wyposa\u017cenia technicznego. Z uwagi na to, prowadzi si\u0119 intensywne badania nad innowacyjnymi rozwi\u0105zaniami technicznymi, kt\u00f3re pomog\u0105 w zmniejszaniu \u015bladu w\u0119glowego sektora budowlanego. Obok technologii wykorzystuj\u0105cych odnawialne \u017ar\u00f3d\u0142a energii, promuje si\u0119 i wdra\u017ca efektywno\u015b\u0107 energetyczn\u0105 oraz inteligentne budownictwo. Okazuje si\u0119, \u017ce automatyka budynk\u00f3w i elektroniczne monitorowanie system\u00f3w technicznych to niezwykle skuteczne \u015brodki do uzyskania znacz\u0105cych oszcz\u0119dno\u015bci energii. Mi\u0119dzy innymi dlatego w dyrektywie EPBD [5] wprowadzono wska\u017anik gotowo\u015bci budynk\u00f3w do obs\u0142ugi inteligentnych sieci. Jest to reakcja na post\u0119p w rozwoju informatycznych system\u00f3w zarz\u0105dzania budynkiem BMS (Building Management System) i BEMS (Building and Energy Management System). W roku 2010 r. wraz z nowelizacj\u0105 dyrektywy 2002\/91\/WE Energy Performance in Buildings Directive (EPBD) [3,4] Unia Europejska wprowadzi\u0142a jako cel \u201dNearly Zero \u2013 Energy Buildings\u201d i wymaga wprowadzenia tego standardu budynku dla nowo wznoszonych obiekt\u00f3w od stycznia 2021 r. we wszystkich krajach cz\u0142onkowskich. Niemal zerowa lub bardzo niska ilo\u015b\u0107 wymaganej energii powinna pochodzi\u0107 w bardzo wysokim stopniu z energii ze \u017ar\u00f3de\u0142 odnawialnych, w tym energii ze \u017ar\u00f3de\u0142 odnawialnych wytwarzanej na miejscu lub w pobli\u017cu budynku. Dla budynk\u00f3w u\u017cyteczno\u015bci publicznej w Polsce zgodnie z obowi\u0105zuj\u0105cymi przepisami [6] oznacza to, \u017ce warto\u015b\u0107 wska\u017anika zapotrzebowania na nieodnawialn\u0105 energi\u0119 pierwotn\u0105 (EP) do ogrzewania, przygotowania ciep\u0142ej wody, ch\u0142odzenia, o\u015bwietlenia wbudowanego oraz przez urz\u0105dzenia pomocnicze w tych systemach nie mo\u017ce przekroczy\u0107 95 kWh\/(m2rok) dla budynk\u00f3w bez systemu ch\u0142odzenia i 120 kWh\/(m2rok) dla budynk\u00f3w z systemem ch\u0142odzenia. W artykule na przyk\u0142adzie obiektu NZEB \u201ePosejdon\u201d w Szczecinie poddanego renowacji i rozbudowie zawarto informacje dotycz\u0105ce rozwi\u0105za\u0144 w zakresie wyposa\u017cenia technicznego, kt\u00f3re umo\u017cliwi\u0142y osi\u0105gni\u0119cie w warunkach polskich wymaganego niskiego poziomu zu\u017cycia nieodnawialnej energii pierwotnej. Mo\u017cna je traktowa\u0107 jako wskaz\u00f3wki pomocne w osi\u0105gni\u0119ciu standardu NZEB w innych obiektach o podobnym charakterze.<\/p>    <\/div>\n<\/div>\n<!-- \/module text -->        <\/div>\n                        <\/div>\n        <\/div>\n                        <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_t70e34 tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_2 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col4-3 tb_2irj35 first\">\n                    <!-- module text -->\n<div  class=\"module module-text tb_y884343   \" data-lazy=\"1\">\n        <div  class=\"tb_text_wrap\">\n        <p><strong>Analizowany obiekt \u2013 dane og\u00f3lne<\/strong><\/p>\n<p style=\"text-align: justify;\">Kompleks us\u0142ugowy \u201ePosejdon\u201d to obecnie najwi\u0119kszy realizowany w Polsce obiekt o niskim zu\u017cyciu energii (NZEB \u2013 Nearly Zero \u2013 Energy Building). Zlokalizowany jest on w \u015bcis\u0142ym centrum miasta Szczecina przy jednej z g\u0142\u00f3wnych arterii miasta i stanowi po\u0142\u0105czenie istniej\u0105cego budynku dawnego Domu Towarowego z zupe\u0142nie now\u0105 dobudowan\u0105 do niego cz\u0119\u015bci\u0105, kt\u00f3re razem b\u0119d\u0105 jedn\u0105 funkcjonaln\u0105 ca\u0142o\u015bci\u0105. Istniej\u0105cy budynek powsta\u0142 28 listopada 1928, a w roku nast\u0119pnym zosta\u0142 oddany do u\u017cytku jako Dom Towarowy \u201eDeFaKa\u201d (Deutsches Familien-Kaufhaus). Mie\u015bci\u0142y si\u0119 w nim sklepy, restauracje, kawiarnie, cukiernia, piwiarnia, bar nocny, ogr\u00f3d zimowy i kabaret, a jego g\u0142\u00f3wn\u0105 atrakcj\u0105 by\u0142a ogromna sala kinowa \u201eUFA Palast\u201d mog\u0105ca pomie\u015bci\u0107 ponad 1200 widz\u00f3w. Architektem obiektu by\u0142 Max Bischoff. W czasie dzia\u0142a\u0144 wojennych gmach DeFaKa uleg\u0142 znacznym zniszczeniom \u2013 w gruzach leg\u0142a w\u00f3wczas cz\u0119\u015b\u0107 kompleksu z sal\u0105 kinow\u0105, a znacznym zniszczeniom uleg\u0142a r\u00f3wnie\u017c modernistyczna fasada. Po wojnie odbudowano zachowan\u0105 cz\u0119\u015b\u0107 budynku \u2013 jednak\u017ce w innymi ni\u017c pierwotnie kszta\u0142cie oraz w ubo\u017cszej formie. W 1951 roku budynek zosta\u0142 ponownie oddany do u\u017cytku ju\u017c jako Powszechny Dom Towarowy i funkcjonowa\u0142 w tym charakterze do 2009 roku. Od 2015 roku w\u0142a\u015bcicielem ca\u0142ego kwarta\u0142u jest szczeci\u0144ska firma Porto Sp. z o.o., kt\u00f3ra w pa\u017adzierniku 2016 r. uzyska\u0142a prawomocne pozwolenie na budow\u0119. Uko\u0144czenie inwestycji jest planowane na koniec 2019 roku. Po przebudowie elewacja zachowanego do dzisiaj budynku odzyska dawny, modernistyczny wygl\u0105d, kt\u00f3ry b\u0119dzie si\u0119 komponowa\u0142 z now\u0105 cz\u0119\u015bci\u0105 kompleksu (rys.1-2).<\/p>\n<p style=\"text-align: justify;\">W kompleksie funkcjonowa\u0107 b\u0119dzie biurowiec o powierzchni u\u017cytkowej niemal 20.000 m2, centrum kongresowe dla blisko 1.000 os\u00f3b oraz dwa hotele nale\u017c\u0105ce do sieci Marriott \u2013 Courtyard by Marriott i Moxy \u2013 kt\u00f3re \u0142\u0105cznie b\u0119d\u0105 oferowa\u0107 255 pokoi hotelowych. Na dw\u00f3ch podziemnych kondygnacjach<\/p>    <\/div>\n<\/div>\n<!-- \/module text -->        <\/div>\n                    <div  data-lazy=\"1\" class=\"module_column tb-column col4-1 tb_5wee35 last\">\n                    <!-- module image -->\n<div  class=\"module module-image tb_e0ht298 image-top   tf_mw\" data-lazy=\"1\">\n        <div class=\"image-wrap tf_rel tf_mw\">\n            <a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys1_.jpg\">\n                   <img decoding=\"async\" src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys1_.jpg\" alt=\"Rys.1.\nWidok na fasad\u0119 historycznej\ncz\u0119\u015bci budynku.\nWizualizacja;\nautor: Federacyjne\nBiuro Architektoniczne\">        <\/a>\n    \n        <\/div>\n    <!-- \/image-wrap -->\n    \n        <div class=\"image-content\">\n                        <div class=\"image-caption tb_text_wrap\">\n            Rys.1.<br \/>\nWidok na fasad\u0119 historycznej\ncz\u0119\u015bci budynku.\nWizualizacja;\nautor: Federacyjne\nBiuro Architektoniczne        <\/div>\n        <!-- \/image-caption -->\n            <\/div>\n    <!-- \/image-content -->\n        <\/div>\n<!-- \/module image --><!-- module image -->\n<div  class=\"module module-image tb_gnjz482 image-top   tf_mw\" data-lazy=\"1\">\n        <div class=\"image-wrap tf_rel tf_mw\">\n            <a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys2_.jpg\">\n                   <img decoding=\"async\" src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys2_.jpg\" alt=\"Rys.2.\nWidok od strony\nul. Partyzant\u00f3w, Wizualizacja;\nautor: Federacyjne\nBiuro Architektoniczne\">        <\/a>\n    \n        <\/div>\n    <!-- \/image-wrap -->\n    \n        <div class=\"image-content\">\n                        <div class=\"image-caption tb_text_wrap\">\n            Rys.2.<br \/>\nWidok od strony\nul. Partyzant\u00f3w, Wizualizacja;\nautor: Federacyjne\nBiuro Architektoniczne        <\/div>\n        <!-- \/image-caption -->\n            <\/div>\n    <!-- \/image-content -->\n        <\/div>\n<!-- \/module image -->        <\/div>\n                        <\/div>\n        <\/div>\n                        <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_em0470 tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_iz8i72 first\">\n                    <!-- module text -->\n<div  class=\"module module-text tb_7b90168   \" data-lazy=\"1\">\n        <div  class=\"tb_text_wrap\">\n        <p style=\"text-align: justify;\">przewidziano miejsca parkingowe dla os\u00f3b zmotoryzowanych i rowerzyst\u00f3w \u2013 strze\u017cony parking pomie\u015bci blisko 300 samochod\u00f3w oraz 100 rower\u00f3w, a tak\u017ce zaoferuje co najmniej 10 miejsc do \u0142adowania aut elektrycznych, myjni\u0119 samochodow\u0105 oraz szatnie i prysznice dla rowerzyst\u00f3w. Na parterze budynku przewidziano cz\u0119\u015b\u0107 handlowo-us\u0142ugow\u0105 o powierzchni 4.600 m2. Na dachu budynku zostanie udost\u0119pniony taras widokowy ze skybarem (ok. 600 m2), z kt\u00f3rego podziwia\u0107 b\u0119dzie mo\u017cna panoram\u0119 Szczecina a\u017c po Jezioro D\u0105bie i rozlewiska Doliny Dolnej Odry. Ca\u0142o\u015bci dope\u0142ni og\u00f3lnodost\u0119pne patio po\u0142o\u017cone na pierwszym pi\u0119trze cz\u0119\u015bci biurowej, gdzie powstanie wysoka na kilkana\u015bcie metr\u00f3w pionowa \u015bciana zieleni.<\/p>\n<p style=\"text-align: justify;\">Ten kompleks b\u0119dzie jednym z najnowocze\u015bniejszych obiekt\u00f3w w Polsce. Samodzielnie b\u0119dzie produkowa\u0107 wi\u0119kszo\u015b\u0107 niezb\u0119dnego ciep\u0142a i ch\u0142odu. Wyposa\u017cony zostanie m.in. w nowoczesne instalacje HVAC oparte na technologii OZE, zasilane przez ogniwa fotowoltaiczne zlokalizowane na dachu budynku, system wykorzystania wody deszczowej w toaletach oraz urz\u0105dzenia wyposa\u017cenia technicznego charakteryzuj\u0105ce si\u0119 bardzo wysok\u0105 efektywno\u015bci\u0105 energetyczn\u0105. Dzi\u0119ki zastosowaniu nowoczesnych, proekologicznych rozwi\u0105za\u0144 ca\u0142y kompleks zredukuje emisj\u0119 CO2 do atmosfery a\u017c o ponad 70% w stosunku do takiego samego budynku, ale zbudowanego w technologii tradycyjnej.<\/p>    <\/div>\n<\/div>\n<!-- \/module text -->        <\/div>\n                        <\/div>\n        <\/div>\n                        <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_l6cf163 tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_2 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col4-3 tb_ejrm164 first\">\n                    <!-- module text -->\n<div  class=\"module module-text tb_uk1k106   \" data-lazy=\"1\">\n        <div  class=\"tb_text_wrap\">\n        <p><strong>Nowoczesne instalacje w kompleksie NZEB \u201ePosejdon\u201d<\/strong><\/p>\n<p style=\"text-align: justify;\">Pod budynkiem wykonano ogromny wymiennik gruntowy, dzi\u0119ki kt\u00f3remu mo\u017cliwe b\u0119dzie pozyskiwanie energii z gruntu (rys.3-4). Wymiennik ten sk\u0142ada si\u0119 z 48 pionowych odwiert\u00f3w o g\u0142\u0119boko\u015bci 300 m ka\u017cdy zlokalizowanych pod p\u0142yt\u0105 fundamentow\u0105 obiektu w obszarze gara\u017cu podziemnego. W ka\u017cdym odwiercie znajduje si\u0119 sonda podw\u00f3jna. Na etapie projektu przyj\u0119to \u015bredni\u0105 moc jednostkow\u0105 sondy gruntowej 50 W\/mb. Pionowe wymienniki gruntowe po\u0142\u0105czono ze studzienkami rozdzielaczowymi zlokalizowanymi pod p\u0142yt\u0105 gara\u017cu. Od studzienek rozdzielaczowych instalacja rurowa zosta\u0142a wprowadzona do pomieszczenia rozdzielni ch\u0142odu. Instalacja nape\u0142niona jest glikolem etylenowym o st\u0119\u017ceniu 28%. W projekcie przyj\u0119to, \u017ce parametry tego czynnika w sezonie zimowym b\u0119d\u0105 wynosi\u0142y 12\/8 oC, a w okresie letnim 26\/30 oC. Przep\u0142yw solanki zapewnia zestaw pompowy sk\u0142adaj\u0105cy si\u0119 z trzech pomp przystosowanych do pracy w systemie 2+1 (dwie pracuj\u0105 + jedna rezerwowa, system pracy pomp naprzemienny). Czynnik z wymiennik\u00f3w gruntowych kierowany jest na dwa wymienniki glikol\/woda (moc 2x400kW) pracuj\u0105ce na potrzeby wewn\u0119trznej wodnej instalacji pomp ciep\u0142a. W okresie zimowym instalacja b\u0119dzie pracowa\u0142a w oparciu o te dwa wymienniki. W przypadku, gdy temperatura na powrocie z p\u0119tli pomp ciep\u0142a osi\u0105gnie warto\u015b\u0107 minimaln\u0105 (6oC) uk\u0142ad przejdzie w tryb pracy, w kt\u00f3rym wymienniki glikol\/woda wspomagane b\u0119d\u0105 przez rezerwow\u0105 pomp\u0119 ciep\u0142a (rys.5). W okresie lata uk\u0142ad ch\u0142odzenia b\u0119dzie dodatkowo wspomagany przez dwie wie\u017ce ch\u0142odnicze wyparne zlokalizowane na dachu budynku.<\/p>\n<p style=\"text-align: justify;\">Ciep\u0142o pozyskane z gruntu pos\u0142u\u017cy do ogrzewania obiektu, dzi\u0119ki wykorzystaniu wysokosprawnych lokalnych pomp ciep\u0142a WLHP w przestrzeni biurowej i us\u0142ugowej, a tak\u017ce dla budynku hotelowego dla potrzeb przygotowania ciep\u0142ej wody. Natomiast w sezonie letnim pozyskany z gruntu ch\u0142\u00f3d wykorzystany zostanie do klimatyzacji przestrzeni biurowej i us\u0142ugowej za pomoc\u0105 lokalnych pomp ciep\u0142a WLHP. W tym celu cz\u0119\u015b\u0107 biurowo \u2013 us\u0142ugow\u0105 kompleksu wyposa\u017cono w 910 inwerterowych pomp ciep\u0142a umieszczonych pod stropem, kt\u00f3re b\u0119d\u0105 odpowiedzialne za utrzymanie wymaganych temperatur w pomieszczeniach. Klasa efektywno\u015bci energetycznej w zastosowanych urz\u0105dzeniach to klasa A+ \u2013 zar\u00f3wno dla funkcji grzania jak i funkcji ch\u0142odzenia. Instalacja pomp ciep\u0142a WLHP b\u0119dzie instalacj\u0105 dwururow\u0105 nape\u0142nion\u0105 wod\u0105 uzdatnion\u0105.<\/p>\n<p style=\"text-align: justify;\">Podstawowym \u017ar\u00f3d\u0142em ciep\u0142a dla uk\u0142adu przygotowania ciep\u0142ej wody dla cz\u0119\u015bci hotelowej b\u0119dzie w\u0119ze\u0142 cieplny dwustopniowy w po\u0142\u0105czeniu szeregowo-r\u00f3wnoleg\u0142ym z zasobnikami ciep\u0142ej wody. Dodatkowo ciep\u0142a woda b\u0119dzie wst\u0119pne podgrzewana przy wykorzystaniu ciep\u0142a pozyskanego z gruntowych wymiennik\u00f3w ciep\u0142a. Do tego celu przewidziano dwa uk\u0142ady \u2013 uk\u0142ad z wymiennikiem woda-woda do wst\u0119pnego podgrzewu wody wodoci\u0105gowej oraz uk\u0142ad z pomp\u0105 ciep\u0142a woda- -woda i dodatkowym wymiennikiem przep\u0142ywowym do podgrzewania wody w obiegu \u0142adowania zasobnik\u00f3w ciep\u0142ej wody. W projekcie przyj\u0119to, \u017ce 50% zapotrzebowania na ciep\u0142\u0105 wod\u0119 b\u0119dzie wytwarzane z wykorzystaniem w\u0119z\u0142a ciep\u0142a, natomiast pozosta\u0142e 50% b\u0119dzie realizowane przez uk\u0142ad OZE. Generowany w ten spos\u00f3b ch\u0142\u00f3d z pompy ciep\u0142a b\u0119dzie obni\u017ca\u0142 temperatur\u0119 wody w instalacji pomp ciep\u0142a WLHP.<\/p>\n<p style=\"text-align: justify;\">Energia elektryczna niezb\u0119dna do zasilania pomocniczych nap\u0119d\u00f3w pracuj\u0105cych w instalacjach grzewczo-ch\u0142odniczych HVAC, pomp obiegowych w uk\u0142adzie OZE i pomp w w\u0119\u017ale cieplnym, elektrycznych podgrzewaczy c.w. przewidzianych w cz\u0119\u015bci biurowej) oraz o\u015bwietlenia wewn\u0119trznego pozyskiwana b\u0119dzie z systemu paneli PV o \u0142\u0105cznej mocy ok. 102,6 kWp. Instalacja zostanie wykonana na dachu budynku i b\u0119dzie si\u0119 sk\u0142ada\u0142a z 342 modu\u0142\u00f3w fotowoltaicznych monokrystalicznych o mocy szczytowej 300 kWp. Planowana roczna produkcja energii elektrycznej z systemu paneli dachowych PV to ok. 81.880 kWh.<\/p>\n<p style=\"text-align: justify;\">O\u015bwietlenie sztuczne w pomieszczeniach o czasowej obecno\u015bci u\u017cytkownik\u00f3w (w\u0119z\u0142y sanitarne, klatki schodowe, parking podziemny) b\u0119dzie kontrolowane za pomoc\u0105 czujnik\u00f3w ruchu. Zastosowanie czujnik\u00f3w ruchu pozwala na uzyskanie miarodajnych oszcz\u0119dno\u015bci p\u0142yn\u0105cych z racjonalnego wykorzystania energii elektrycznej. Dodatkowo o\u015bwietlenie korytarzy, holi do\u015bwietlonych \u015bwiat\u0142em dziennym umo\u017cliwi wyeliminowanie sytuacji bezcelowego u\u017cytkowania \u015bwiat\u0142a sztucznego w chwili, gdy promieniowanie s\u0142oneczne zapewnia wystarczaj\u0105cy poziom nat\u0119\u017cenia o\u015bwietlenia. Wykorzystanie o\u015bwietlenia sztucznego jest zale\u017cne bezpo\u015brednio od pory dnia, pory roku oraz aktualnych warunk\u00f3w atmosferycznych.<\/p>\n<p style=\"text-align: justify;\">W budynku b\u0119d\u0105 zainstalowane lampy LED. Dzi\u0119ki niskiemu zapotrzebowaniu na energi\u0119 elektryczn\u0105 przyczyniaj\u0105 si\u0119 one do ograniczenia zu\u017cycia energii, co w spos\u00f3b bezpo\u015bredni wp\u0142ywa na ograniczenie emisji szkodliwego dla \u015brodowiska dwutlenku w\u0119gla.<\/p>\n<p style=\"text-align: justify;\">W budynku przewidziano wiele rozwi\u0105za\u0144 pozwalaj\u0105cych ograniczy\u0107 zu\u017cycie zimnej wody. Przewidziano wykorzystanie uzdatnionej wody deszczowej (system wody szarej) do sp\u0142ukiwania toalet, podlewania dach\u00f3w zielonych oraz zielonej \u015bciany. W zwi\u0105zku z powy\u017cszym zaprojektowano osobn\u0105 instalacj\u0119 wody uzdatnionej doprowadzon\u0105 do w\u0119z\u0142\u00f3w sanitarnych cz\u0119\u015bci biurowej budynku oraz dla potrzeb podlewania zieleni na og\u00f3lnodost\u0119pnym patio zlokalizowanym nad kondygnacj\u0105 parterow\u0105.<\/p>    <\/div>\n<\/div>\n<!-- \/module text -->        <\/div>\n                    <div  data-lazy=\"1\" class=\"module_column tb-column col4-1 tb_ndx6165 last\">\n                    <!-- module image -->\n<div  class=\"module module-image tb_t05c169 image-top   tf_mw\" data-lazy=\"1\">\n        <div class=\"image-wrap tf_rel tf_mw\">\n            <a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys3_.jpg\">\n                   <img decoding=\"async\" src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys3_.jpg\" alt=\"Rys. 3.\nWykonywanie odwiert\u00f3w pod wymiennik gruntowy\n[www.posejdocenter.pl]\">        <\/a>\n    \n        <\/div>\n    <!-- \/image-wrap -->\n    \n        <div class=\"image-content\">\n                        <div class=\"image-caption tb_text_wrap\">\n            Rys. 3.<br \/>\nWykonywanie odwiert\u00f3w pod wymiennik gruntowy\n[www.posejdocenter.pl]        <\/div>\n        <!-- \/image-caption -->\n            <\/div>\n    <!-- \/image-content -->\n        <\/div>\n<!-- \/module image --><!-- module image -->\n<div  class=\"module module-image tb_6did658 image-top   tf_mw\" data-lazy=\"1\">\n        <div class=\"image-wrap tf_rel tf_mw\">\n            <a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys4_.jpg\">\n                   <img decoding=\"async\" src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys4_.jpg\" alt=\"Rys. 4.\nPor\u00f3wnanie g\u0142\u0119boko\u015bci\nwymiennika\ngruntowego do najwy\u017cszych\nbudowli\nw Szczecinie oraz\nPa\u0142acu Kultury\ni Nauki w Warszawie\">        <\/a>\n    \n        <\/div>\n    <!-- \/image-wrap -->\n    \n        <div class=\"image-content\">\n                        <div class=\"image-caption tb_text_wrap\">\n            Rys. 4.<br \/>\nPor\u00f3wnanie g\u0142\u0119boko\u015bci\nwymiennika\ngruntowego do najwy\u017cszych\nbudowli\nw Szczecinie oraz\nPa\u0142acu Kultury\ni Nauki w Warszawie        <\/div>\n        <!-- \/image-caption -->\n            <\/div>\n    <!-- \/image-content -->\n        <\/div>\n<!-- \/module image --><!-- module image -->\n<div  class=\"module module-image tb_0u54274 image-top   tf_mw\" data-lazy=\"1\">\n        <div class=\"image-wrap tf_rel tf_mw\">\n            <a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys5_.jpg\">\n                   <img decoding=\"async\" src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys5_.jpg\" alt=\"Rys. 5.\nSchemat \u017ar\u00f3d\u0142a ciep\u0142a. 1 \u2013 wymiennik gruntowy (48 pionowych odwiert\u00f3w z podw\u00f3jnymi sondami), 2 \u2013 studzienki rozdzielaczowe, 3 \u2013 zestaw pompowy\n(trzy pompy przystosowane do pracy w systemie 2+1), 4 \u2013 wymienniki woda \/ glikol (moc 2x400kW), 5 \u2013 rezerwowa pompa ciep\u0142a, 6 \u2013 dwie wie\u017ce ch\u0142odnicze\nwyparne zabudowane na dachu budynku, 7 \u2013 zestaw pomp obiegowych (trzy pompy przystosowane do pracy w systemie 2+1), 8 \u2013 w\u0119ze\u0142 cieplny\ndwustopniowy w po\u0142\u0105czeniu szeregowo-r\u00f3wnoleg\u0142ym z zasobnikami ciep\u0142ej wody dla cz\u0119\u015bci hotelowej, 9 \u2013 wymiennik woda-woda do wst\u0119pnego podgrzewu\nwody wodoci\u0105gowej, 10 \u2013 pompa ciep\u0142a woda-woda do przygotowania ciep\u0142ej wody, 11 \u2013 wymiennik przep\u0142ywowy do podgrzewu wody w obiegu\n\u0142adowania zasobnik\u00f3w ciep\u0142ej wody, WSHP 1-6 \u2013 910 lokalnych pomp ciep\u0142a tworz\u0105cych 6 dwururowych p\u0119tli\">        <\/a>\n    \n        <\/div>\n    <!-- \/image-wrap -->\n    \n        <div class=\"image-content\">\n                        <div class=\"image-caption tb_text_wrap\">\n            Rys. 5.<br \/>\nSchemat \u017ar\u00f3d\u0142a ciep\u0142a. 1 \u2013 wymiennik gruntowy (48 pionowych odwiert\u00f3w z podw\u00f3jnymi sondami), 2 \u2013 studzienki rozdzielaczowe, 3 \u2013 zestaw pompowy\n(trzy pompy przystosowane do pracy w systemie 2+1), 4 \u2013 wymienniki woda \/ glikol (moc 2x400kW), 5 \u2013 rezerwowa pompa ciep\u0142a, 6 \u2013 dwie wie\u017ce ch\u0142odnicze\nwyparne zabudowane na dachu budynku, 7 \u2013 zestaw pomp obiegowych (trzy pompy przystosowane do pracy w systemie 2+1), 8 \u2013 w\u0119ze\u0142 cieplny\ndwustopniowy w po\u0142\u0105czeniu szeregowo-r\u00f3wnoleg\u0142ym z zasobnikami ciep\u0142ej wody dla cz\u0119\u015bci hotelowej, 9 \u2013 wymiennik woda-woda do wst\u0119pnego podgrzewu\nwody wodoci\u0105gowej, 10 \u2013 pompa ciep\u0142a woda-woda do przygotowania ciep\u0142ej wody, 11 \u2013 wymiennik przep\u0142ywowy do podgrzewu wody w obiegu\n\u0142adowania zasobnik\u00f3w ciep\u0142ej wody, WSHP 1-6 \u2013 910 lokalnych pomp ciep\u0142a tworz\u0105cych 6 dwururowych p\u0119tli        <\/div>\n        <!-- \/image-caption -->\n            <\/div>\n    <!-- \/image-content -->\n        <\/div>\n<!-- \/module image -->        <\/div>\n                        <\/div>\n        <\/div>\n                        <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_fnd750 tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_imjk53 first\">\n                    <!-- module text -->\n<div  class=\"module module-text tb_mr5o861   \" data-lazy=\"1\">\n        <div  class=\"tb_text_wrap\">\n        <p style=\"text-align: justify;\">W w\u0119z\u0142ach sanitarnych zastosowane zosta\u0142y automatyczne elektrozawory odcinaj\u0105ce dop\u0142yw wody podczas nieobecno\u015bci u\u017cytkownik\u00f3w w pomieszczeniach. System ten pe\u0142ni funkcj\u0119 ograniczenia zu\u017cycia wody w przypadku rozszczelnienia instalacji, awarii baterii umywalkowych, sp\u0142uczek lub pozostawienia niezamkni\u0119tych zawor\u00f3w baterii umywalkowych przez u\u017cytkownik\u00f3w. W w\u0119z\u0142ach przeznaczonych dla u\u017cytkownik\u00f3w zastosowane zostan\u0105 elektroniczne baterie umywalkowe wyposa\u017cone w czujniki ruchu, ograniczaj\u0105ce zu\u017cycie wody.<\/p>    <\/div>\n<\/div>\n<!-- \/module text -->        <\/div>\n                        <\/div>\n        <\/div>\n                        <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_467v646 tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_2 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col4-3 tb_14u7647 first\">\n                    <!-- module text -->\n<div  class=\"module module-text tb_0log670   \" data-lazy=\"1\">\n        <div  class=\"tb_text_wrap\">\n        <p><strong>Ogrzewanie i ch\u0142odzenie cz\u0119\u015bci biurowo \u2013 us\u0142ugowej<\/strong><\/p>\n<p style=\"text-align: justify;\">W cz\u0119\u015bci biurowo \u2013 us\u0142ugowej przewidziano g\u0142\u00f3wnie ogrzewanie i ch\u0142odzenie powietrzne. Na dachu budynku oraz w pomieszczeniach technicznych zlokalizowano centrale wentylacyjne wyposa\u017cone w wysokosprawne urz\u0105dzenia do odzysku ciep\u0142a (wymienniki obrotowe lub krzy\u017cowe), filtry klasy F7 na nawiewie, nagrzewnice zasilane roztworem glikolu etylenowego oraz filtry klasy G4 na wywiewie. Centrale do cz\u0119\u015bci biurowej dodatkowo wyposa\u017cone b\u0119d\u0105 w ch\u0142odnice zasilane roztworem glikolu etylenowego, a powietrze nawiewane za tymi centralami b\u0119dzie nawil\u017cane do wilgotno\u015bci 40%. Powietrze \u015bwie\u017ce z central zostanie rozprowadzone sieci\u0105 przewod\u00f3w wentylacyjnych do poszczeg\u00f3lnych pomieszcze\u0144 w budynku. Na wyj\u015bciach na poszczeg\u00f3lne kondygnacje przewidziano klapy przeciwpo\u017carowe. Na ka\u017cdej kondygnacji na odej\u015bciu od g\u0142\u00f3wnych szacht\u00f3w zainstalowane zostan\u0105 przepustnice odcinaj\u0105ce sterowane z systemu BMS, umo\u017cliwiaj\u0105ce wymian\u0119 powietrza tylko na tej kondygnacji, w czasie gdy inne kondygnacje b\u0119d\u0105 odci\u0119te. Rozprowadzenie powietrza do poszczeg\u00f3lnych nawiewnik\u00f3w wykonane zostanie zgodnie z aran\u017cacj\u0105 architektoniczn\u0105 poszczeg\u00f3lnych pomieszcze\u0144 i wyposa\u017cone b\u0119dzie w regulator sta\u0142ego wydatku CAV. System automatyki central wentylacyjnych kontrolowa\u0107 b\u0119dzie obroty silnik\u00f3w wentylator\u00f3w, utrzymuj\u0105c sta\u0142e ci\u015bnienie dyspozycyjne za central\u0105. Dla pomieszcze\u0144, w kt\u00f3rych zak\u0142ada si\u0119 okresowe przebywanie ludzi przewiduje si\u0119 zamontowanie regulator\u00f3w zmiennego wydatku powietrza VAV na nawiewie i wywiewie ze \u015bciennym detektorem obecno\u015bci powoduj\u0105cym otwarcie dop\u0142ywu powietrza. Uk\u0142ad wentylacji zaprojektowano ze zmienn\u0105 wydajno\u015bci\u0105 zale\u017cn\u0105 od jako\u015bci powietrza wewn\u0119trznego, sterowany z systemu automatyki i BMS. Wydajno\u015b\u0107 wentylacji b\u0119dzie obni\u017cana do minimum podczas nieobecno\u015bci u\u017cytkownik\u00f3w obiektu. Wprowadzone rozwi\u0105zania powinny w znacz\u0105cym stopniu wp\u0142yn\u0105\u0107 na obni\u017cenie zu\u017cycia energii przez systemy wentylacji i klimatyzacji.<\/p>    <\/div>\n<\/div>\n<!-- \/module text -->        <\/div>\n                    <div  data-lazy=\"1\" class=\"module_column tb-column col4-1 tb_rz1k647 last\">\n                    <!-- module image -->\n<div  class=\"module module-image tb_qmsw897 image-top   tf_mw\" data-lazy=\"1\">\n        <div class=\"image-wrap tf_rel tf_mw\">\n            <a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys6_.jpg\">\n                   <img decoding=\"async\" src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys6_.jpg\" alt=\"Rys. 6.\nSchemat dwururowej instalacji\nz wieloma pompami ciep\u0142a\n(WLHP)\">        <\/a>\n    \n        <\/div>\n    <!-- \/image-wrap -->\n    \n        <div class=\"image-content\">\n                        <div class=\"image-caption tb_text_wrap\">\n            Rys. 6.<br \/>\nSchemat dwururowej instalacji\nz wieloma pompami ciep\u0142a\n(WLHP)        <\/div>\n        <!-- \/image-caption -->\n            <\/div>\n    <!-- \/image-content -->\n        <\/div>\n<!-- \/module image --><!-- module image -->\n<div  class=\"module module-image tb_retv997 image-top   tf_mw\" data-lazy=\"1\">\n        <div class=\"image-wrap tf_rel tf_mw\">\n            <a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys7_.jpg\">\n                   <img decoding=\"async\" src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys7_.jpg\" alt=\"Rys.7.\nPompa ciep\u0142a przy\u0142\u0105czona\ndo instalacji\nwodnej przez uk\u0142ad\nrurowy z zaworem\nregulacyjnym, filtrem\nsiatkowym\ni zaworami odcinaj\u0105cymi\">        <\/a>\n    \n        <\/div>\n    <!-- \/image-wrap -->\n    \n        <div class=\"image-content\">\n                        <div class=\"image-caption tb_text_wrap\">\n            Rys.7.<br \/>\nPompa ciep\u0142a przy\u0142\u0105czona\ndo instalacji\nwodnej przez uk\u0142ad\nrurowy z zaworem\nregulacyjnym, filtrem\nsiatkowym\ni zaworami odcinaj\u0105cymi        <\/div>\n        <!-- \/image-caption -->\n            <\/div>\n    <!-- \/image-content -->\n        <\/div>\n<!-- \/module image -->        <\/div>\n                        <\/div>\n        <\/div>\n                        <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_xa8b968 tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_sq9j970 first\">\n                    <!-- module text -->\n<div  class=\"module module-text tb_v7n5310   \" data-lazy=\"1\">\n        <div  class=\"tb_text_wrap\">\n        <p style=\"text-align: justify;\">Ogrzewanie i ch\u0142odzenie przestrzeni biurowo-us\u0142ugowej b\u0119dzie realizowane jak wspomniano wcze\u015bniej za pomoc\u0105 urz\u0105dze\u0144 typu pompa ciep\u0142a woda- -powietrze (WLHP) pod\u0142\u0105czonych przewodami do p\u0119tli wodnej dwururowej o zmiennych parametrach pracy dla lata i zimy (rys.6).<\/p>\n<p style=\"text-align: justify;\">Systemy WLHP (Water Loop Heat Pump) opisywane w literaturze r\u00f3wnie\u017c jako WSHP (Water Source Heat Pump) s\u0105 alternatyw\u0105 dla konwencjonalnych uk\u0142ad\u00f3w klimatyzacyjno \u2013 grzewczych. W ostatnich latach s\u0105 coraz ch\u0119tniej stosowane w obiektach, w kt\u00f3rych wyst\u0119puje r\u00f3\u017cne zapotrzebowanie na energi\u0119 do ch\u0142odzenia i ogrzewania w poszczeg\u00f3lnych obszarach i pomieszczeniach. Wykorzystuj\u0105c uk\u0142ad WLHP mo\u017cna ciep\u0142o lub ch\u0142\u00f3d odbiera\u0107 z pomieszcze\u0144, gdzie jest go w nadmiarze i wykorzystywa\u0107 w innym miejscu. Odwracalny obieg ch\u0142odniczy tych pomp pozwala na utrzymanie wymaganej temperatury w pomieszczeniach lub strefie niezale\u017cnie od tego, czy wymagaj\u0105 one w danym momencie grzania, czy te\u017c ch\u0142odzenia. Dzi\u0119ki temu w tym samym czasie w jednym obiekcie mo\u017cna jedne pomieszczenia ogrzewa\u0107, a inne ch\u0142odzi\u0107 korzystaj\u0105c z jednej instalacji. System WLHP jest uk\u0142adem wielu pomp ciep\u0142a typu woda\/powietrze po\u0142\u0105czonych jedn\u0105 instalacj\u0105 hydrauliczn\u0105. W kompleksie us\u0142ugowym \u201ePosejdon\u201d zamontowano 910 takich pomp pracuj\u0105cych w sze\u015bciu uk\u0142adach. Ka\u017cdy z nich umo\u017cliwia transport ciep\u0142a i ch\u0142odu pomi\u0119dzy powietrzem a wod\u0105 z wykorzystaniem uk\u0142adu spr\u0119\u017carkowego pomp ciep\u0142a. Podczas pracy w trybie ch\u0142odzenia energia pobierana z pomieszczenia przekazywana jest do wody kr\u0105\u017c\u0105cej w p\u0119tli wodnej. Podczas pracy w trybie grzania ciep\u0142o jest pobierane z p\u0119tli wodnej i oddawane do powietrza, kt\u00f3re ogrzewa pomieszczenie. G\u0142\u00f3wn\u0105 cech\u0105 tego systemu jest wytwarzanie ciep\u0142a lub ch\u0142odu bezpo\u015brednio w miejscu, w kt\u00f3rym jest wykorzystywane (czyli jest to system zdecentralizowany), co jest bardzo korzystne w aspekcie efektywno\u015bci energetycznej. Uk\u0142ad natomiast potrzebuje centralnego \u017ar\u00f3d\u0142a ciep\u0142a oraz \u017ar\u00f3d\u0142a ch\u0142odu. W przypadku kompleksu \u201ePosejdon\u201d \u017ar\u00f3d\u0142em ciep\u0142a jest grunt. Ciep\u0142o pobierane za pomoc\u0105 wymiennik\u00f3w gruntowych w wymiennikach glikol\/woda przekazywane jest wodzie kr\u0105\u017c\u0105cej w p\u0119tlach pomp ciep\u0142a. Przy maksymalnym zapotrzebowaniu na ciep\u0142o wymienniki glikol\/woda mog\u0105 by\u0107 wspomagane dodatkowa pomp\u0105 ciep\u0142a. \u0179r\u00f3d\u0142em ch\u0142odu r\u00f3wnie\u017c jest wymiennik gruntowy wspomagany wie\u017cami ch\u0142odniczymi (rys.5).<\/p>\n<p style=\"text-align: justify;\">Pojedyncze pompy ciep\u0142a posiadaj\u0105 certyfikat wysokiej klasy efektywno\u015bci energetycznej (A+), o wska\u017anikach: COP &gt; 4,1, EER &gt; 5,9, LW max &lt; 37,5 dBA.<\/p>\n<p style=\"text-align: justify;\">Zadaniem instalacji p\u0119tli wodnej jest dostarczanie, odbieranie oraz akumulacja energii. Kr\u0105\u017c\u0105ca woda pe\u0142ni funkcj\u0119 czynnika transportuj\u0105cego energi\u0119 pomi\u0119dzy pomieszczeniami lub ich strefami. W zale\u017cno\u015bci od trybu pracy jest dolnym lub g\u00f3rnym \u017ar\u00f3d\u0142em ciep\u0142a dla zainstalowanych pomp ciep\u0142a. Jednocze\u015bnie pe\u0142ni ona funkcj\u0119 akumulatora energii, kt\u00f3ra swobodnie mo\u017ce zosta\u0107 wykorzystana przez ka\u017cd\u0105 z pomp ciep\u0142a znajduj\u0105c\u0105 si\u0119 w p\u0119tli. Gdy temperatura wody w p\u0119tli mie\u015bci si\u0119 w granicach od 14 do 25 \u00b0C uk\u0142ad znajduje si\u0119 w r\u00f3wnowadze termodynamicznej. Oznacza to, \u017ce pompy ciep\u0142a w budynku mog\u0105 pracowa\u0107 r\u00f3wnocze\u015bnie w trybie ch\u0142odzenia jak i grzania (w zale\u017cno\u015bci od potrzeb indywidualnych pomieszcze\u0144) bez konieczno\u015bci dostarczania lub odbierania energii z centralnego \u017ar\u00f3d\u0142a ciep\u0142a lub ch\u0142odu (wymiennika gruntowego). Wp\u0142ywa to na obni\u017cenie koszt\u00f3w eksploatacyjnych systemu grzewczo- ch\u0142odz\u0105cego w obiekcie.<\/p>\n<p style=\"text-align: justify;\">Ka\u017cda z 910 pomp ciep\u0142a b\u0119dzie pod\u0142\u0105czona do instalacji przez uk\u0142ad rurowy z zaworem regulacyjnym, filtrem siatkowym i zaworami odcinaj\u0105cymi (rys. 7). Ze wzgl\u0119du na zmienne zapotrzebowanie na ch\u0142\u00f3d i ciep\u0142o obs\u0142ugiwanych przez p\u0119tl\u0119 wodn\u0105 pomieszcze\u0144 istotne jest zastosowanie bardzo precyzyjnej regulacji przep\u0142ywu. Jako\u015b\u0107 tej regulacji jest bardzo istotna z uwagi zar\u00f3wno na dotrzymanie za\u0142o\u017conych temperatur w pomieszczeniach, jak i w kontek\u015bcie minimalizacji zu\u017cycia energii elektrycznej do nap\u0119du pomp wymuszaj\u0105cych obieg czynnika w pier\u015bcieniu wodnym. Z tego powodu jako zawory regulacyjne zastosowano nowoczesne zawory r\u00f3wnowa\u017c\u0105ce ABQM z nap\u0119dem cyfrowym NovoCon\u00ae firmy Danfoss, dzi\u0119ki kt\u00f3rym uk\u0142ad b\u0119dzie w stanie zapewni\u0107 uzyskanie komfortu cieplnego w pomieszczeniach, znacz\u0105cych oszcz\u0119dno\u015bci energii i co ma ogromne znaczenie dla sprawnej eksploatacji zapewniaj\u0105c bardziej precyzyjn\u0105 wsp\u00f3\u0142prac\u0119 armatury regulacyjno- -r\u00f3wnowa\u017c\u0105cej z systemem BMS. Zastosowane urz\u0105dzenia umo\u017cliwi\u0105 znaczn\u0105 oszcz\u0119dno\u015b\u0107 czasu podczas monta\u017cu, zdalne uruchomienie systemu i wykonanie nastawy na zaworze. Pozwol\u0105 tak\u017ce wykry\u0107 potencjalne nieprawid\u0142owo\u015bci pracy uk\u0142adu lub b\u0142\u0119dy monta\u017cowe oraz wystarczaj\u0105co precyzyjnie okre\u015bli\u0107 indywidualne zu\u017cycie ciep\u0142a lub ch\u0142odu w obs\u0142ugiwanych pomieszczeniach (rejestr i alokacja zu\u017cycia energii).<\/p>\n<p style=\"text-align: justify;\">Zaw\u00f3r ABQM jest zaworem regulacyjnym z wbudowanym regulatorem ci\u015bnienia, kt\u00f3ry utrzymuje sta\u0142y spadek ci\u015bnienia w cz\u0119\u015bci regulacyjnej. Ten sta\u0142y spadek ci\u015bnienia jest niezale\u017cny od waha\u0144 ci\u015bnienia w instalacji (b\u0119d\u0105cych konsekwencj\u0105 zmiennych przep\u0142yw\u00f3w), co zabezpiecza instalacj\u0119 przed zjawiskiem tzw. nadprzep\u0142yw\u00f3w oraz pozwala na utrzymanie niezmiennej charakterystyki zaworu regulacyjnego. Ma to bezpo\u015bredni wp\u0142yw na utrzymanie wysokiego komfortu cieplnego w pomieszczeniach przy jednoczesnym zapewnieniu optymalnego przep\u0142ywu czynnika. Konstrukcja zaworu jest tak zaprojektowana, i\u017c dla poprawnej pracy zaworu wystarczy zapewnienie minimalnego spadku ci\u015bnienia na zaworze na poziomie 16 kPa, co ma bezpo\u015bredni wp\u0142yw na dob\u00f3r pomp w uk\u0142adach hydraulicznych \u2013 wp\u0142ywa na obni\u017cenie koszt\u00f3w eksploatacyjnych wynikaj\u0105cych z koszt\u00f3w pompowania.<\/p>\n<p style=\"text-align: justify;\">Dzi\u0119ki wsp\u00f3\u0142pracy zaworu z si\u0142ownikiem NovoCon mo\u017ce on by\u0107 wykorzystywany w systemach BMS (Building Management System). Ten krokowo-cyfrowy nap\u0119d posiada cztery grupy funkcji, kt\u00f3re powoduj\u0105, i\u017c jest to obecnie unikalne rozwi\u0105zanie dedykowane instalacji HVAC:<\/p>\n<p style=\"text-align: justify;\">\u2013 funkcja komunikacji \u2013 umo\u017cliwia wpi\u0119cie 64 nap\u0119d\u00f3w do jednego obwodu, dokonywanie zdalnych nastaw (obliczeniowych przep\u0142yw\u00f3w ich ewentualnych zmian, wywo\u0142ania funkcji p\u0142ukania czy odpowietrzania, rozpoznanie stan\u00f3w awaryjnych i ich przyczyny), monitoring, analiz\u0119 i diagnostyk\u0119 pracy uk\u0142adu. Funkcja ta ma bezpo\u015bredni wp\u0142yw na koszty uruchamiania oraz eksploatacji instalacji;<\/p>\n<p style=\"text-align: justify;\">\u2013 funkcja modu\u0142\u00f3w wej\u015bcia\/wyj\u015bcia (Input\/Output) \u2013 umo\u017cliwia wsp\u00f3\u0142prac\u0119 zaworu z wieloma obiektami, jak: czujniki ruchu, otwarcia okna, temperatur, wilgotno\u015bci, zanieczyszczenia, itd. Modu\u0142y te mog\u0105 by\u0107 bezpo\u015brednio wpi\u0119te do nap\u0119du bez konieczno\u015bci zastosowania dodatkowych sterownik\u00f3w czy przeka\u017anik\u00f3w. Umo\u017cliwia to zapewnienie optymalnej pracy uk\u0142adu przy jednoczesnym maksymalnym komforcie ciep\u0142ym u\u017cytkownika oraz ci\u0105g\u0142y monitoring parametr\u00f3w pompy ciep\u0142a;<\/p>\n<p style=\"text-align: justify;\">\u2013 funkcja zarz\u0105dzania energi\u0105 (Energy Management) \u2013 umo\u017cliwia monitoring i kontrol\u0119 minimalnej r\u00f3\u017cnicy temperatur na odbiorniku, nastaw\u0119 i kontrol\u0119 r\u00f3\u017cnicy temperatur oraz temperatury powrotu, ograniczenie minimalnej temperatury powrotu, ograniczenie maksymalnej temperatury powrotu. Funkcja ta zapewnia poprawn\u0105 prac\u0119 uk\u0142ad\u00f3w grzania i ch\u0142odzenia dzi\u0119ki mo\u017cliwo\u015bci utrzymania warunk\u00f3w obliczeniowych dla ka\u017cdych warunk\u00f3w pracy instalacji;<\/p>\n<p style=\"text-align: justify;\">\u2013 funkcja alokacji energii \u2013 umo\u017cliwia wykorzystanie wbudowanych zaawansowanych funkcji pomiaru zu\u017cycia energii przez pompy ciep\u0142a oraz jej kontroli. Rozwi\u0105zanie to obecnie jest stosowane jako mo\u017cliwo\u015bci alokacji energii wed\u0142ug faktycznego zu\u017cycia a nie wed\u0142ug metr\u00f3w kwadratowych zajmowanej powierzchni. Funkcja ta mo\u017ce by\u0107 wykorzystywana do analizy systemu, obci\u0105\u017cenia, efektywno\u015bci, sprawno\u015bci oraz natychmiastowej interwencji w przypadkach marnowania energii czy te\u017c jej zu\u017cycia w miejscach, gdzie nikt z tego nie korzysta.<\/p>\n<p style=\"text-align: justify;\">Standard instalacji HVAC w obiekcie \u201ePosejdon\u201d daleko wykracza poza obowi\u0105zuj\u0105ce obecnie normy. Zastosowane technologie pozwoli\u0142y na uzyskanie presti\u017cowego certyfikatu ekologicznego BREEAM w najnowszej wersji New Construction 2016 na poziomie EXCELLENT. Ocena w ramach certyfikacji BREEAM odbywa si\u0119 w dziesi\u0119ciu kategoriach: Zarz\u0105dzanie, Zdrowie i dobre samopoczucie, Energia, Transport, Woda, Materia\u0142y, Odpady, Wykorzystanie terenu i ekologia, Zanieczyszczenia oraz Innowacje. Aby m\u00f3c ubiega\u0107 si\u0119 o certyfikat w ka\u017cdej z tych kategorii trzeba zdoby\u0107 okre\u015blon\u0105 liczb\u0119 punkt\u00f3w krytycznych. Istnieje te\u017c obszerna lista dodatkowych wymaga\u0144, za spe\u0142nienie kt\u00f3rych otrzymuje si\u0119 kolejne punkty. Ich suma decyduje o przyznaniu certyfikatu w pi\u0119ciostopniowej skali. Poziom EXCELLENT jest stopniem czwartym, kt\u00f3ry potwierdza, \u017ce obiekt spe\u0142ni\u0142 ponad 70 procent wy\u015brubowanych wytycznych brytyjskiej organizacji certyfikuj\u0105cej. Certyfikat BREEAM potwierdza, \u017ce dzi\u0119ki zastosowaniu wielu rozwi\u0105za\u0144 redukuj\u0105cych zu\u017cycie energii budynek jest proekologiczny i oszcz\u0119dny dla jego w\u0142a\u015bciciela oraz i\u017c zosta\u0142 wykonany wg najnowszych, europejskich norm i standard\u00f3w, dzi\u0119ki czemu zapewnia najwy\u017cszy komfort jego u\u017cytkownikom.<\/p>    <\/div>\n<\/div>\n<!-- \/module text -->        <\/div>\n                        <\/div>\n        <\/div>\n                        <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_hv0q494 tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_m3u5494 first\">\n                    <!-- module text -->\n<div  class=\"module module-text tb_ftzg872   \" data-lazy=\"1\">\n        <div  class=\"tb_text_wrap\">\n        <p><strong>System BMS w \u201ePosejdonie\u201d<\/strong><\/p>\n<p style=\"text-align: justify;\">Obiekt \u201ePosejdon\u201d zawiera pomieszczenia o r\u00f3\u017cnym charakterze (m.in. hotelowe, biurowe, sale konferencyjne, lokale handlowo-us\u0142ugowe, serwerownie, maszynownie, gara\u017ce), kt\u00f3re wymagaj\u0105 odr\u0119bnego systemu gwarantuj\u0105cego zr\u00f3\u017cnicowany poziom komfortu i bezpiecze\u0144stwa. Aby wszystkie te elementy stanowi\u0142y sp\u00f3jn\u0105 i dobrze funkcjonuj\u0105c\u0105 ca\u0142o\u015b\u0107, w obiekcie funkcjonowa\u0107 b\u0119dzie zaawansowany system automatycznej regulacji i sterowania \u2013 BMS (Building Management System) uzupe\u0142niony o funkcjonalno\u015bci pozwalaj\u0105ce na zarz\u0105dzanie zu\u017cyciem energii. System zapewni w\u0142a\u015bciwe parametry \u015brodowiska wewn\u0119trznego (komfortu u\u017cytkownik\u00f3w) przy racjonalnym zu\u017cyciu energii. B\u0119dzie \u017ar\u00f3d\u0142em informacji, analiz i wytycznych umo\u017cliwiaj\u0105cych kompleksowe spojrzenie na zu\u017cycie energii w obiekcie. W postaci interaktywnych grafik umo\u017cliwi wizualizacj\u0119 zu\u017cycia energii i zarz\u0105dzanie energi\u0105 oraz jej alokacj\u0119, pozwoli na por\u00f3wnanie zu\u017cycia energii w stosunku do poprzednich okres\u00f3w rozliczeniowych, wprowadzanie plan\u00f3w energetycznych, ci\u0105g\u0142e optymalizowanie zu\u017cycia energii, popraw\u0119 efektywno\u015bci energetycznej i wska\u017anik\u00f3w eksploatacyjnych przez ca\u0142y okres u\u017cytkowania budynku. Dzi\u0119ki temu mo\u017cna b\u0119dzie podejmowa\u0107 trafne decyzje przyczyniaj\u0105ce si\u0119 do zminimalizowania zu\u017cycia energii w budynku. W zwi\u0105zku z tym, \u017ce najwi\u0119ksze zapotrzebowanie na energi\u0119 jest zwi\u0105zane z o\u015bwietleniem, ogrzewaniem i klimatyzacj\u0105 zastosowane zosta\u0142y, szczeg\u00f3lnie w tych instalacjach, nowoczesne rozwi\u0105zania wspieraj\u0105ce popraw\u0119 efektywno\u015bci energetycznej. Uk\u0142ady wentylacji zaprojektowano ze zmienn\u0105 wydajno\u015bci\u0105 zale\u017cn\u0105 od jako\u015bci powietrza wewn\u0119trznego. Wydajno\u015b\u0107 wentylacji b\u0119dzie obni\u017cana do minimum podczas nieobecno\u015bci u\u017cytkownik\u00f3w obiektu. Optymalna temperatura wewn\u0119trzna b\u0119dzie kontrolowana za pomoc\u0105 odpowiedniego zag\u0119szczenia czujnik\u00f3w temperatury z mo\u017cliwo\u015bci\u0105 regulacji temperatury odr\u0119bnie w poszczeg\u00f3lnych pomieszczeniach. Dodatkowo zastosowano monitorowanie otwarcia okien przez u\u017cytkownik\u00f3w. W takim przypadku wy\u0142\u0105czane s\u0105 \u017ar\u00f3d\u0142a ciep\u0142a\/ch\u0142odu (pompy ciep\u0142a) na danej powierzchni lub w pomieszczeniu. U\u017cytkownicy obiektu b\u0119d\u0105 mogli samodzielnie kontrolowa\u0107 o\u015bwietlenie oraz temperatur\u0119 za pomoc\u0105 zadajnik\u00f3w w pomieszczeniach.<\/p>\n<p style=\"text-align: justify;\">Szczeg\u00f3\u0142owo opomiarowane zostanie w budynku m.in.:<\/p>\n<p style=\"text-align: justify;\">\u2013\u2013 zu\u017cycie wody,<\/p>\n<p style=\"text-align: justify;\">\u2013\u2013 zu\u017cycie energii elektrycznej,<\/p>\n<p style=\"text-align: justify;\">\u2013\u2013 zu\u017cycie ciep\u0142a i ch\u0142odu<\/p>    <\/div>\n<\/div>\n<!-- \/module text -->        <\/div>\n                        <\/div>\n        <\/div>\n                        <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_x26f747 tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_a90w748 first\">\n                    <!-- module text -->\n<div  class=\"module module-text tb_cr8z413   \" data-lazy=\"1\">\n        <div  class=\"tb_text_wrap\">\n        <p><strong>Podsumowanie<\/strong><\/p>\n<p style=\"text-align: justify;\">W artykule skoncentrowano si\u0119 na nowoczesnych technologiach z u\u017cyciem energii odnawialnej wdro\u017conych w kompleksie us\u0142ugowym \u201ePosejdon\u201d. Ten najwi\u0119kszy w Polsce NZEB mo\u017cna traktowa\u0107 jako obiekt referencyjny. Jest on wyposa\u017cony mi\u0119dzy innymi w systemy fotowoltaiczne, w uk\u0142ad pozyskiwania energii dla potrzeb grzania i ch\u0142odzenia zrealizowany w oparciu o pionowe wymienniki gruntowe i wykorzystanie pomp ciep\u0142a pracuj\u0105cych w uk\u0142adzie hydraulicznym p\u0119tli wodnej (WLHP). Budynek zosta\u0142 zaprojektowany tak, aby s\u0142u\u017cy\u0142 tak\u017ce jako laboratorium do badania mo\u017cliwo\u015bci zastosowania zaimplementowanych w nim innowacyjnych strategii s\u0142u\u017c\u0105cych wysokiej efektywno\u015bci energetycznej i zmniejszeniu emisji gaz\u00f3w cieplarnianych. Rozwi\u0105zania przedstawione w artykule mo\u017cna traktowa\u0107 jako zbi\u00f3r dobrych praktyk w zakresie realizacji budynk\u00f3w w standardzie NZEB.<\/p>    <\/div>\n<\/div>\n<!-- \/module text -->        <\/div>\n                        <\/div>\n        <\/div>\n                        <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_mp6h570 tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_yp9z571 first\">\n                    <!-- module text -->\n<div  class=\"module module-text tb_j343683   \" data-lazy=\"1\">\n        <div  class=\"tb_text_wrap\">\n        <p><strong>BIBLIOGRAFIA<\/strong><\/p>\n<p style=\"text-align: justify;\">[1] COM (2011) 112 final, The Committee report for the EP and the Council, the European Economic and Social Committee and the Committee of the Regions \u2013 A Roadmap for moving to a competitive low carbon economy in 2050. Pobrane z adresu: https:\/\/eur-lex.europa.eu\/ LexUriServ\/LexUriServ.do?uri=COM:2011:0112:FIN:EN:PDF<\/p>\n<p style=\"text-align: justify;\">[2] COM (2013) 483 final\/2. The Committee report for the EP and the Council \u2013 The progress of member countries in increasing the number of buildings with nearly zero energy use, 7.10.2013 r. Pobrane z adresu: https:\/\/ ec.europa.eu\/energy\/en\/topics\/energy \u2013 efficiency\/buildings<\/p>\n<p style=\"text-align: justify;\">[3] EPBD (2002). Directive 2002\/91\/WE of the European Parliament and of the Council of 16 December 2002 on the energy performance of buildings. OJ L 1\/65 04.01.2003.<\/p>\n<p style=\"text-align: justify;\">[4] EPBD (2010). Directive 2010\/31\/UE of the European Parliament and the Council of 19 Mai 2010 on the energy performance of buildings (recast). OJ L 153 18.06.2010.<\/p>\n<p style=\"text-align: justify;\">[5] EPBD (2018). Directive (EU) 2018\/844 of the European Parliament and of the council of 30 May 2018 amending Directive 2010\/31\/EU on the energy performance of buildings and Directive 2012\/27\/EU on energy efficiency. Off. J. Eur. Union 2018, 156, 75\u201391.<\/p>\n<p style=\"text-align: justify;\">[6] Obwieszczenie Ministra Infrastruktury i Rozwoju z dnia 17 lipca 2015 r. w sprawie og\u0142oszenia jednolitego tekstu rozporz\u0105dzenia Ministra Infrastruktury w sprawie warunk\u00f3w technicznych, jakim powinny odpowiada\u0107 budynki i ich usytuowanie. Za\u0142\u0105cznik 2. Wymagania izolacyjno\u015bci cieplnej i inne wymagania zwi\u0105zane z oszcz\u0119dno\u015bci\u0105 energii<\/p>\n<p style=\"text-align: justify;\">[7] Rozporz\u0105dzenie Ministra Infrastruktury z dnia 12 kwietnia 2002 r. w sprawie warunk\u00f3w technicznych, jakim powinny odpowiada\u0107 budynki i ich usytuowanie. Dz.U. 2002 Nr 75, poz. 690<\/p>\n<p style=\"text-align: justify;\">[8] Pirczewski M., Figiel E., Leciej-Pirczewska D.: \u201eNowoczesny kompleks us\u0142ugowy POSEJDON w Szczecinie\u201d. In\u017cynieria i Budownictwo, 5\/20<\/p>    <\/div>\n<\/div>\n<!-- \/module text -->        <\/div>\n                        <\/div>\n        <\/div>\n        <\/div>\n<!--\/themify_builder_content-->","protected":false},"excerpt":{"rendered":"<p>In Szczecin a mixed-use complex \u201cPosejdon\u201d is being constructed. It will be the first NZEB (Nearly Zero \u2013 Energy<br \/>\nBuilding) in Poland that meets the strict ecological standards that all buildings will have to meet after January 2021.<br \/>\nCompared to a similar building constructed with traditional techniques, the building has significantly lower CO2<br \/>\nemissions. The project was presented at the COP24 United Nations Climate Change Conference in Katowice. The<br \/>\n\u201cPosejdon\u201d service complex consists of two hotels, modern offices and a small commercial section.<br \/>\nThere are very interesting and modern installations in the complex, which are presented in the paper. The building<br \/>\nuses a geothermal energy system for the needs of heating and cooling, which is composed of 48 vertical heat<br \/>\nexchangers located in 300-metre long ground boreholes under the foundation slab, connected with over 900 highly<br \/>\nefficient, inverter heat pumps. The decentralized system of heat pumps in such a big building is unique even in<br \/>\nEurope. The electrical energy necessary for the operation of the entire system will be obtained from 342 photovoltaic<br \/>\npanels located on the roof of the building. The renewable energy technologies implemented in the \u201cPosejdon\u201d<br \/>\nbuilding, serve as a reference to export management and design strategies to other NZEB with similar characteristics.<\/p>\n","protected":false},"featured_media":0,"parent":0,"menu_order":0,"template":"","meta":[],"tags":[737,736],"tematyka":[615],"class_list":["post-6547","artykul","type-artykul","status-publish","hentry","tag-energy-efficiency-renewable-energy","tag-nearly-zero-energy-buildings-modern-building-installations","tematyka-buildings-with-low-energy-consumption","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author",""],"ptb_metabox":{"ptb_artykul_text_1":["EWA FIGIEL","DOROTA LECIEJ-PIRCZEWSKA"],"ptb_artykul_text_2":"10.36119\/15.2019.11.2","ptb_artykul_numer_miesi_cznika":"11\/2019 instal p. 24-30","ptb_artykul_info_autor":"dr in\u017c. Ewa Figiel \u2013 Wydzia\u0142 Budownictwa i Architektury, Zachodniopomorski Uniwersytet Technologiczny w Szczecinie, e-mail:figiel@zut.\r\nedu.pl, ORCID ID: https:\/\/orcid.org\/0000-0001-7034-371X\r\ndr in\u017c. Dorota Leciej-Pirczewska \u2013 Wydzia\u0142 Budownictwa i Architektury, Zachodniopomorski Uniwersytet Technologiczny w Szczecinie,\r\ne-mail: dlp@zut.edu.pl, ORCID ID: https:\/\/orcid.org\/0000-0003-1676-1683","ptb_artykul_orcid":[" https:\/\/orcid.org\/0000-0001-7034-371X"," https:\/\/orcid.org\/0000-0003-1676-1683"]},"ptb_taxonomy":{"post_tag":[{"term_id":737,"name":"energy efficiency; renewable energy","slug":"energy-efficiency-renewable-energy","term_group":0,"term_taxonomy_id":737,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":736,"name":"Nearly Zero Energy Buildings; modern building installations","slug":"nearly-zero-energy-buildings-modern-building-installations","term_group":0,"term_taxonomy_id":736,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"tematyka":[{"term_id":615,"name":"Buildings with low energy consumption","slug":"buildings-with-low-energy-consumption","term_group":0,"term_taxonomy_id":615,"taxonomy":"tematyka","description":"","parent":0,"count":2,"filter":"raw"}]},"ptb_featured_image":null,"builder_content":"<p><strong>Wprowadzenie <\/strong><\/p><p style=\"text-align: justify;\">Aby wesprze\u0107 realizacj\u0119 globalnego planu dzia\u0142a\u0144 w obszarze klimatu, UE zaproponowa\u0142a nowe cele na 2030 r. [1] w ramach podejmowanych wysi\u0142k\u00f3w na rzecz przej\u015bcia na gospodark\u0119 niskoemisyjn\u0105 i ograniczenia emisji gaz\u00f3w cieplarnianych o 80\u201395% w perspektywie do 2050 r. \u015arodkiem do osi\u0105gni\u0119cia tego zamierzenia jest mi\u0119dzy innymi dekarbonizacja zasob\u00f3w budowlanych. W por\u00f3wnaniu do innych sektor\u00f3w budownictwo jest uznawane za ten obszar, w kt\u00f3rym osi\u0105gni\u0119cie tego ambitnego celu uwa\u017cane jest za stosunkowo \u0142atwe do zrealizowania. Jednak mimo pierwszych znacz\u0105cych sukces\u00f3w budownictwo w UE jest nadal jeszcze dalekie od osi\u0105gni\u0119cia neutralnego dla \u015brodowiska bilansu emisji dwutlenku w\u0119gla. Wiadomym jest, \u017ce spos\u00f3b w jaki budujemy i modernizujemy w chwili obecnej nasze budynki b\u0119dzie mia\u0142 wp\u0142yw na ich emisje nie tylko w tej ale i przysz\u0142ej po\u0142owie XXI wieku ze wzgl\u0119du na stosunkowo du\u017c\u0105 trwa\u0142o\u015b\u0107 substancji budowlanej i jej wyposa\u017cenia technicznego. Z uwagi na to, prowadzi si\u0119 intensywne badania nad innowacyjnymi rozwi\u0105zaniami technicznymi, kt\u00f3re pomog\u0105 w zmniejszaniu \u015bladu w\u0119glowego sektora budowlanego. Obok technologii wykorzystuj\u0105cych odnawialne \u017ar\u00f3d\u0142a energii, promuje si\u0119 i wdra\u017ca efektywno\u015b\u0107 energetyczn\u0105 oraz inteligentne budownictwo. Okazuje si\u0119, \u017ce automatyka budynk\u00f3w i elektroniczne monitorowanie system\u00f3w technicznych to niezwykle skuteczne \u015brodki do uzyskania znacz\u0105cych oszcz\u0119dno\u015bci energii. Mi\u0119dzy innymi dlatego w dyrektywie EPBD [5] wprowadzono wska\u017anik gotowo\u015bci budynk\u00f3w do obs\u0142ugi inteligentnych sieci. Jest to reakcja na post\u0119p w rozwoju informatycznych system\u00f3w zarz\u0105dzania budynkiem BMS (Building Management System) i BEMS (Building and Energy Management System). W roku 2010 r. wraz z nowelizacj\u0105 dyrektywy 2002\/91\/WE Energy Performance in Buildings Directive (EPBD) [3,4] Unia Europejska wprowadzi\u0142a jako cel \u201dNearly Zero \u2013 Energy Buildings\u201d i wymaga wprowadzenia tego standardu budynku dla nowo wznoszonych obiekt\u00f3w od stycznia 2021 r. we wszystkich krajach cz\u0142onkowskich. Niemal zerowa lub bardzo niska ilo\u015b\u0107 wymaganej energii powinna pochodzi\u0107 w bardzo wysokim stopniu z energii ze \u017ar\u00f3de\u0142 odnawialnych, w tym energii ze \u017ar\u00f3de\u0142 odnawialnych wytwarzanej na miejscu lub w pobli\u017cu budynku. Dla budynk\u00f3w u\u017cyteczno\u015bci publicznej w Polsce zgodnie z obowi\u0105zuj\u0105cymi przepisami [6] oznacza to, \u017ce warto\u015b\u0107 wska\u017anika zapotrzebowania na nieodnawialn\u0105 energi\u0119 pierwotn\u0105 (EP) do ogrzewania, przygotowania ciep\u0142ej wody, ch\u0142odzenia, o\u015bwietlenia wbudowanego oraz przez urz\u0105dzenia pomocnicze w tych systemach nie mo\u017ce przekroczy\u0107 95 kWh\/(m2rok) dla budynk\u00f3w bez systemu ch\u0142odzenia i 120 kWh\/(m2rok) dla budynk\u00f3w z systemem ch\u0142odzenia. W artykule na przyk\u0142adzie obiektu NZEB \u201ePosejdon\u201d w Szczecinie poddanego renowacji i rozbudowie zawarto informacje dotycz\u0105ce rozwi\u0105za\u0144 w zakresie wyposa\u017cenia technicznego, kt\u00f3re umo\u017cliwi\u0142y osi\u0105gni\u0119cie w warunkach polskich wymaganego niskiego poziomu zu\u017cycia nieodnawialnej energii pierwotnej. Mo\u017cna je traktowa\u0107 jako wskaz\u00f3wki pomocne w osi\u0105gni\u0119ciu standardu NZEB w innych obiektach o podobnym charakterze.<\/p>\n<p><strong>Analizowany obiekt \u2013 dane og\u00f3lne<\/strong><\/p> <p style=\"text-align: justify;\">Kompleks us\u0142ugowy \u201ePosejdon\u201d to obecnie najwi\u0119kszy realizowany w Polsce obiekt o niskim zu\u017cyciu energii (NZEB \u2013 Nearly Zero \u2013 Energy Building). Zlokalizowany jest on w \u015bcis\u0142ym centrum miasta Szczecina przy jednej z g\u0142\u00f3wnych arterii miasta i stanowi po\u0142\u0105czenie istniej\u0105cego budynku dawnego Domu Towarowego z zupe\u0142nie now\u0105 dobudowan\u0105 do niego cz\u0119\u015bci\u0105, kt\u00f3re razem b\u0119d\u0105 jedn\u0105 funkcjonaln\u0105 ca\u0142o\u015bci\u0105. Istniej\u0105cy budynek powsta\u0142 28 listopada 1928, a w roku nast\u0119pnym zosta\u0142 oddany do u\u017cytku jako Dom Towarowy \u201eDeFaKa\u201d (Deutsches Familien-Kaufhaus). Mie\u015bci\u0142y si\u0119 w nim sklepy, restauracje, kawiarnie, cukiernia, piwiarnia, bar nocny, ogr\u00f3d zimowy i kabaret, a jego g\u0142\u00f3wn\u0105 atrakcj\u0105 by\u0142a ogromna sala kinowa \u201eUFA Palast\u201d mog\u0105ca pomie\u015bci\u0107 ponad 1200 widz\u00f3w. Architektem obiektu by\u0142 Max Bischoff. W czasie dzia\u0142a\u0144 wojennych gmach DeFaKa uleg\u0142 znacznym zniszczeniom \u2013 w gruzach leg\u0142a w\u00f3wczas cz\u0119\u015b\u0107 kompleksu z sal\u0105 kinow\u0105, a znacznym zniszczeniom uleg\u0142a r\u00f3wnie\u017c modernistyczna fasada. Po wojnie odbudowano zachowan\u0105 cz\u0119\u015b\u0107 budynku \u2013 jednak\u017ce w innymi ni\u017c pierwotnie kszta\u0142cie oraz w ubo\u017cszej formie. W 1951 roku budynek zosta\u0142 ponownie oddany do u\u017cytku ju\u017c jako Powszechny Dom Towarowy i funkcjonowa\u0142 w tym charakterze do 2009 roku. Od 2015 roku w\u0142a\u015bcicielem ca\u0142ego kwarta\u0142u jest szczeci\u0144ska firma Porto Sp. z o.o., kt\u00f3ra w pa\u017adzierniku 2016 r. uzyska\u0142a prawomocne pozwolenie na budow\u0119. Uko\u0144czenie inwestycji jest planowane na koniec 2019 roku. Po przebudowie elewacja zachowanego do dzisiaj budynku odzyska dawny, modernistyczny wygl\u0105d, kt\u00f3ry b\u0119dzie si\u0119 komponowa\u0142 z now\u0105 cz\u0119\u015bci\u0105 kompleksu (rys.1-2).<\/p> <p style=\"text-align: justify;\">W kompleksie funkcjonowa\u0107 b\u0119dzie biurowiec o powierzchni u\u017cytkowej niemal 20.000 m2, centrum kongresowe dla blisko 1.000 os\u00f3b oraz dwa hotele nale\u017c\u0105ce do sieci Marriott \u2013 Courtyard by Marriott i Moxy \u2013 kt\u00f3re \u0142\u0105cznie b\u0119d\u0105 oferowa\u0107 255 pokoi hotelowych. Na dw\u00f3ch podziemnych kondygnacjach<\/p>\n<a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys1_.jpg\"> <img src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys1_.jpg\" alt=\"Rys.1. Widok na fasad\u0119 historycznej cz\u0119\u015bci budynku. Wizualizacja; autor: Federacyjne Biuro Architektoniczne\"> <\/a> Rys.1.<br \/> Widok na fasad\u0119 historycznej cz\u0119\u015bci budynku. Wizualizacja; autor: Federacyjne Biuro Architektoniczne\n<a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys2_.jpg\"> <img src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys2_.jpg\" alt=\"Rys.2. Widok od strony ul. Partyzant\u00f3w, Wizualizacja; autor: Federacyjne Biuro Architektoniczne\"> <\/a> Rys.2.<br \/> Widok od strony ul. Partyzant\u00f3w, Wizualizacja; autor: Federacyjne Biuro Architektoniczne\n<p style=\"text-align: justify;\">przewidziano miejsca parkingowe dla os\u00f3b zmotoryzowanych i rowerzyst\u00f3w \u2013 strze\u017cony parking pomie\u015bci blisko 300 samochod\u00f3w oraz 100 rower\u00f3w, a tak\u017ce zaoferuje co najmniej 10 miejsc do \u0142adowania aut elektrycznych, myjni\u0119 samochodow\u0105 oraz szatnie i prysznice dla rowerzyst\u00f3w. Na parterze budynku przewidziano cz\u0119\u015b\u0107 handlowo-us\u0142ugow\u0105 o powierzchni 4.600 m2. Na dachu budynku zostanie udost\u0119pniony taras widokowy ze skybarem (ok. 600 m2), z kt\u00f3rego podziwia\u0107 b\u0119dzie mo\u017cna panoram\u0119 Szczecina a\u017c po Jezioro D\u0105bie i rozlewiska Doliny Dolnej Odry. Ca\u0142o\u015bci dope\u0142ni og\u00f3lnodost\u0119pne patio po\u0142o\u017cone na pierwszym pi\u0119trze cz\u0119\u015bci biurowej, gdzie powstanie wysoka na kilkana\u015bcie metr\u00f3w pionowa \u015bciana zieleni.<\/p> <p style=\"text-align: justify;\">Ten kompleks b\u0119dzie jednym z najnowocze\u015bniejszych obiekt\u00f3w w Polsce. Samodzielnie b\u0119dzie produkowa\u0107 wi\u0119kszo\u015b\u0107 niezb\u0119dnego ciep\u0142a i ch\u0142odu. Wyposa\u017cony zostanie m.in. w nowoczesne instalacje HVAC oparte na technologii OZE, zasilane przez ogniwa fotowoltaiczne zlokalizowane na dachu budynku, system wykorzystania wody deszczowej w toaletach oraz urz\u0105dzenia wyposa\u017cenia technicznego charakteryzuj\u0105ce si\u0119 bardzo wysok\u0105 efektywno\u015bci\u0105 energetyczn\u0105. Dzi\u0119ki zastosowaniu nowoczesnych, proekologicznych rozwi\u0105za\u0144 ca\u0142y kompleks zredukuje emisj\u0119 CO2 do atmosfery a\u017c o ponad 70% w stosunku do takiego samego budynku, ale zbudowanego w technologii tradycyjnej.<\/p>\n<p><strong>Nowoczesne instalacje w kompleksie NZEB \u201ePosejdon\u201d<\/strong><\/p> <p style=\"text-align: justify;\">Pod budynkiem wykonano ogromny wymiennik gruntowy, dzi\u0119ki kt\u00f3remu mo\u017cliwe b\u0119dzie pozyskiwanie energii z gruntu (rys.3-4). Wymiennik ten sk\u0142ada si\u0119 z 48 pionowych odwiert\u00f3w o g\u0142\u0119boko\u015bci 300 m ka\u017cdy zlokalizowanych pod p\u0142yt\u0105 fundamentow\u0105 obiektu w obszarze gara\u017cu podziemnego. W ka\u017cdym odwiercie znajduje si\u0119 sonda podw\u00f3jna. Na etapie projektu przyj\u0119to \u015bredni\u0105 moc jednostkow\u0105 sondy gruntowej 50 W\/mb. Pionowe wymienniki gruntowe po\u0142\u0105czono ze studzienkami rozdzielaczowymi zlokalizowanymi pod p\u0142yt\u0105 gara\u017cu. Od studzienek rozdzielaczowych instalacja rurowa zosta\u0142a wprowadzona do pomieszczenia rozdzielni ch\u0142odu. Instalacja nape\u0142niona jest glikolem etylenowym o st\u0119\u017ceniu 28%. W projekcie przyj\u0119to, \u017ce parametry tego czynnika w sezonie zimowym b\u0119d\u0105 wynosi\u0142y 12\/8 oC, a w okresie letnim 26\/30 oC. Przep\u0142yw solanki zapewnia zestaw pompowy sk\u0142adaj\u0105cy si\u0119 z trzech pomp przystosowanych do pracy w systemie 2+1 (dwie pracuj\u0105 + jedna rezerwowa, system pracy pomp naprzemienny). Czynnik z wymiennik\u00f3w gruntowych kierowany jest na dwa wymienniki glikol\/woda (moc 2x400kW) pracuj\u0105ce na potrzeby wewn\u0119trznej wodnej instalacji pomp ciep\u0142a. W okresie zimowym instalacja b\u0119dzie pracowa\u0142a w oparciu o te dwa wymienniki. W przypadku, gdy temperatura na powrocie z p\u0119tli pomp ciep\u0142a osi\u0105gnie warto\u015b\u0107 minimaln\u0105 (6oC) uk\u0142ad przejdzie w tryb pracy, w kt\u00f3rym wymienniki glikol\/woda wspomagane b\u0119d\u0105 przez rezerwow\u0105 pomp\u0119 ciep\u0142a (rys.5). W okresie lata uk\u0142ad ch\u0142odzenia b\u0119dzie dodatkowo wspomagany przez dwie wie\u017ce ch\u0142odnicze wyparne zlokalizowane na dachu budynku.<\/p> <p style=\"text-align: justify;\">Ciep\u0142o pozyskane z gruntu pos\u0142u\u017cy do ogrzewania obiektu, dzi\u0119ki wykorzystaniu wysokosprawnych lokalnych pomp ciep\u0142a WLHP w przestrzeni biurowej i us\u0142ugowej, a tak\u017ce dla budynku hotelowego dla potrzeb przygotowania ciep\u0142ej wody. Natomiast w sezonie letnim pozyskany z gruntu ch\u0142\u00f3d wykorzystany zostanie do klimatyzacji przestrzeni biurowej i us\u0142ugowej za pomoc\u0105 lokalnych pomp ciep\u0142a WLHP. W tym celu cz\u0119\u015b\u0107 biurowo \u2013 us\u0142ugow\u0105 kompleksu wyposa\u017cono w 910 inwerterowych pomp ciep\u0142a umieszczonych pod stropem, kt\u00f3re b\u0119d\u0105 odpowiedzialne za utrzymanie wymaganych temperatur w pomieszczeniach. Klasa efektywno\u015bci energetycznej w zastosowanych urz\u0105dzeniach to klasa A+ \u2013 zar\u00f3wno dla funkcji grzania jak i funkcji ch\u0142odzenia. Instalacja pomp ciep\u0142a WLHP b\u0119dzie instalacj\u0105 dwururow\u0105 nape\u0142nion\u0105 wod\u0105 uzdatnion\u0105.<\/p> <p style=\"text-align: justify;\">Podstawowym \u017ar\u00f3d\u0142em ciep\u0142a dla uk\u0142adu przygotowania ciep\u0142ej wody dla cz\u0119\u015bci hotelowej b\u0119dzie w\u0119ze\u0142 cieplny dwustopniowy w po\u0142\u0105czeniu szeregowo-r\u00f3wnoleg\u0142ym z zasobnikami ciep\u0142ej wody. Dodatkowo ciep\u0142a woda b\u0119dzie wst\u0119pne podgrzewana przy wykorzystaniu ciep\u0142a pozyskanego z gruntowych wymiennik\u00f3w ciep\u0142a. Do tego celu przewidziano dwa uk\u0142ady \u2013 uk\u0142ad z wymiennikiem woda-woda do wst\u0119pnego podgrzewu wody wodoci\u0105gowej oraz uk\u0142ad z pomp\u0105 ciep\u0142a woda- -woda i dodatkowym wymiennikiem przep\u0142ywowym do podgrzewania wody w obiegu \u0142adowania zasobnik\u00f3w ciep\u0142ej wody. W projekcie przyj\u0119to, \u017ce 50% zapotrzebowania na ciep\u0142\u0105 wod\u0119 b\u0119dzie wytwarzane z wykorzystaniem w\u0119z\u0142a ciep\u0142a, natomiast pozosta\u0142e 50% b\u0119dzie realizowane przez uk\u0142ad OZE. Generowany w ten spos\u00f3b ch\u0142\u00f3d z pompy ciep\u0142a b\u0119dzie obni\u017ca\u0142 temperatur\u0119 wody w instalacji pomp ciep\u0142a WLHP.<\/p> <p style=\"text-align: justify;\">Energia elektryczna niezb\u0119dna do zasilania pomocniczych nap\u0119d\u00f3w pracuj\u0105cych w instalacjach grzewczo-ch\u0142odniczych HVAC, pomp obiegowych w uk\u0142adzie OZE i pomp w w\u0119\u017ale cieplnym, elektrycznych podgrzewaczy c.w. przewidzianych w cz\u0119\u015bci biurowej) oraz o\u015bwietlenia wewn\u0119trznego pozyskiwana b\u0119dzie z systemu paneli PV o \u0142\u0105cznej mocy ok. 102,6 kWp. Instalacja zostanie wykonana na dachu budynku i b\u0119dzie si\u0119 sk\u0142ada\u0142a z 342 modu\u0142\u00f3w fotowoltaicznych monokrystalicznych o mocy szczytowej 300 kWp. Planowana roczna produkcja energii elektrycznej z systemu paneli dachowych PV to ok. 81.880 kWh.<\/p> <p style=\"text-align: justify;\">O\u015bwietlenie sztuczne w pomieszczeniach o czasowej obecno\u015bci u\u017cytkownik\u00f3w (w\u0119z\u0142y sanitarne, klatki schodowe, parking podziemny) b\u0119dzie kontrolowane za pomoc\u0105 czujnik\u00f3w ruchu. Zastosowanie czujnik\u00f3w ruchu pozwala na uzyskanie miarodajnych oszcz\u0119dno\u015bci p\u0142yn\u0105cych z racjonalnego wykorzystania energii elektrycznej. Dodatkowo o\u015bwietlenie korytarzy, holi do\u015bwietlonych \u015bwiat\u0142em dziennym umo\u017cliwi wyeliminowanie sytuacji bezcelowego u\u017cytkowania \u015bwiat\u0142a sztucznego w chwili, gdy promieniowanie s\u0142oneczne zapewnia wystarczaj\u0105cy poziom nat\u0119\u017cenia o\u015bwietlenia. Wykorzystanie o\u015bwietlenia sztucznego jest zale\u017cne bezpo\u015brednio od pory dnia, pory roku oraz aktualnych warunk\u00f3w atmosferycznych.<\/p> <p style=\"text-align: justify;\">W budynku b\u0119d\u0105 zainstalowane lampy LED. Dzi\u0119ki niskiemu zapotrzebowaniu na energi\u0119 elektryczn\u0105 przyczyniaj\u0105 si\u0119 one do ograniczenia zu\u017cycia energii, co w spos\u00f3b bezpo\u015bredni wp\u0142ywa na ograniczenie emisji szkodliwego dla \u015brodowiska dwutlenku w\u0119gla.<\/p> <p style=\"text-align: justify;\">W budynku przewidziano wiele rozwi\u0105za\u0144 pozwalaj\u0105cych ograniczy\u0107 zu\u017cycie zimnej wody. Przewidziano wykorzystanie uzdatnionej wody deszczowej (system wody szarej) do sp\u0142ukiwania toalet, podlewania dach\u00f3w zielonych oraz zielonej \u015bciany. W zwi\u0105zku z powy\u017cszym zaprojektowano osobn\u0105 instalacj\u0119 wody uzdatnionej doprowadzon\u0105 do w\u0119z\u0142\u00f3w sanitarnych cz\u0119\u015bci biurowej budynku oraz dla potrzeb podlewania zieleni na og\u00f3lnodost\u0119pnym patio zlokalizowanym nad kondygnacj\u0105 parterow\u0105.<\/p>\n<a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys3_.jpg\"> <img src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys3_.jpg\" alt=\"Rys. 3. Wykonywanie odwiert\u00f3w pod wymiennik gruntowy [www.posejdocenter.pl]\"> <\/a> Rys. 3.<br \/> Wykonywanie odwiert\u00f3w pod wymiennik gruntowy [www.posejdocenter.pl]\n<a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys4_.jpg\"> <img src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys4_.jpg\" alt=\"Rys. 4. Por\u00f3wnanie g\u0142\u0119boko\u015bci wymiennika gruntowego do najwy\u017cszych budowli w Szczecinie oraz Pa\u0142acu Kultury i Nauki w Warszawie\"> <\/a> Rys. 4.<br \/> Por\u00f3wnanie g\u0142\u0119boko\u015bci wymiennika gruntowego do najwy\u017cszych budowli w Szczecinie oraz Pa\u0142acu Kultury i Nauki w Warszawie\n<a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys5_.jpg\"> <img src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys5_.jpg\" alt=\"Rys. 5. Schemat \u017ar\u00f3d\u0142a ciep\u0142a. 1 \u2013 wymiennik gruntowy (48 pionowych odwiert\u00f3w z podw\u00f3jnymi sondami), 2 \u2013 studzienki rozdzielaczowe, 3 \u2013 zestaw pompowy (trzy pompy przystosowane do pracy w systemie 2+1), 4 \u2013 wymienniki woda \/ glikol (moc 2x400kW), 5 \u2013 rezerwowa pompa ciep\u0142a, 6 \u2013 dwie wie\u017ce ch\u0142odnicze wyparne zabudowane na dachu budynku, 7 \u2013 zestaw pomp obiegowych (trzy pompy przystosowane do pracy w systemie 2+1), 8 \u2013 w\u0119ze\u0142 cieplny dwustopniowy w po\u0142\u0105czeniu szeregowo-r\u00f3wnoleg\u0142ym z zasobnikami ciep\u0142ej wody dla cz\u0119\u015bci hotelowej, 9 \u2013 wymiennik woda-woda do wst\u0119pnego podgrzewu wody wodoci\u0105gowej, 10 \u2013 pompa ciep\u0142a woda-woda do przygotowania ciep\u0142ej wody, 11 \u2013 wymiennik przep\u0142ywowy do podgrzewu wody w obiegu \u0142adowania zasobnik\u00f3w ciep\u0142ej wody, WSHP 1-6 \u2013 910 lokalnych pomp ciep\u0142a tworz\u0105cych 6 dwururowych p\u0119tli\"> <\/a> Rys. 5.<br \/> Schemat \u017ar\u00f3d\u0142a ciep\u0142a. 1 \u2013 wymiennik gruntowy (48 pionowych odwiert\u00f3w z podw\u00f3jnymi sondami), 2 \u2013 studzienki rozdzielaczowe, 3 \u2013 zestaw pompowy (trzy pompy przystosowane do pracy w systemie 2+1), 4 \u2013 wymienniki woda \/ glikol (moc 2x400kW), 5 \u2013 rezerwowa pompa ciep\u0142a, 6 \u2013 dwie wie\u017ce ch\u0142odnicze wyparne zabudowane na dachu budynku, 7 \u2013 zestaw pomp obiegowych (trzy pompy przystosowane do pracy w systemie 2+1), 8 \u2013 w\u0119ze\u0142 cieplny dwustopniowy w po\u0142\u0105czeniu szeregowo-r\u00f3wnoleg\u0142ym z zasobnikami ciep\u0142ej wody dla cz\u0119\u015bci hotelowej, 9 \u2013 wymiennik woda-woda do wst\u0119pnego podgrzewu wody wodoci\u0105gowej, 10 \u2013 pompa ciep\u0142a woda-woda do przygotowania ciep\u0142ej wody, 11 \u2013 wymiennik przep\u0142ywowy do podgrzewu wody w obiegu \u0142adowania zasobnik\u00f3w ciep\u0142ej wody, WSHP 1-6 \u2013 910 lokalnych pomp ciep\u0142a tworz\u0105cych 6 dwururowych p\u0119tli\n<p style=\"text-align: justify;\">W w\u0119z\u0142ach sanitarnych zastosowane zosta\u0142y automatyczne elektrozawory odcinaj\u0105ce dop\u0142yw wody podczas nieobecno\u015bci u\u017cytkownik\u00f3w w pomieszczeniach. System ten pe\u0142ni funkcj\u0119 ograniczenia zu\u017cycia wody w przypadku rozszczelnienia instalacji, awarii baterii umywalkowych, sp\u0142uczek lub pozostawienia niezamkni\u0119tych zawor\u00f3w baterii umywalkowych przez u\u017cytkownik\u00f3w. W w\u0119z\u0142ach przeznaczonych dla u\u017cytkownik\u00f3w zastosowane zostan\u0105 elektroniczne baterie umywalkowe wyposa\u017cone w czujniki ruchu, ograniczaj\u0105ce zu\u017cycie wody.<\/p>\n<p><strong>Ogrzewanie i ch\u0142odzenie cz\u0119\u015bci biurowo \u2013 us\u0142ugowej<\/strong><\/p> <p style=\"text-align: justify;\">W cz\u0119\u015bci biurowo \u2013 us\u0142ugowej przewidziano g\u0142\u00f3wnie ogrzewanie i ch\u0142odzenie powietrzne. Na dachu budynku oraz w pomieszczeniach technicznych zlokalizowano centrale wentylacyjne wyposa\u017cone w wysokosprawne urz\u0105dzenia do odzysku ciep\u0142a (wymienniki obrotowe lub krzy\u017cowe), filtry klasy F7 na nawiewie, nagrzewnice zasilane roztworem glikolu etylenowego oraz filtry klasy G4 na wywiewie. Centrale do cz\u0119\u015bci biurowej dodatkowo wyposa\u017cone b\u0119d\u0105 w ch\u0142odnice zasilane roztworem glikolu etylenowego, a powietrze nawiewane za tymi centralami b\u0119dzie nawil\u017cane do wilgotno\u015bci 40%. Powietrze \u015bwie\u017ce z central zostanie rozprowadzone sieci\u0105 przewod\u00f3w wentylacyjnych do poszczeg\u00f3lnych pomieszcze\u0144 w budynku. Na wyj\u015bciach na poszczeg\u00f3lne kondygnacje przewidziano klapy przeciwpo\u017carowe. Na ka\u017cdej kondygnacji na odej\u015bciu od g\u0142\u00f3wnych szacht\u00f3w zainstalowane zostan\u0105 przepustnice odcinaj\u0105ce sterowane z systemu BMS, umo\u017cliwiaj\u0105ce wymian\u0119 powietrza tylko na tej kondygnacji, w czasie gdy inne kondygnacje b\u0119d\u0105 odci\u0119te. Rozprowadzenie powietrza do poszczeg\u00f3lnych nawiewnik\u00f3w wykonane zostanie zgodnie z aran\u017cacj\u0105 architektoniczn\u0105 poszczeg\u00f3lnych pomieszcze\u0144 i wyposa\u017cone b\u0119dzie w regulator sta\u0142ego wydatku CAV. System automatyki central wentylacyjnych kontrolowa\u0107 b\u0119dzie obroty silnik\u00f3w wentylator\u00f3w, utrzymuj\u0105c sta\u0142e ci\u015bnienie dyspozycyjne za central\u0105. Dla pomieszcze\u0144, w kt\u00f3rych zak\u0142ada si\u0119 okresowe przebywanie ludzi przewiduje si\u0119 zamontowanie regulator\u00f3w zmiennego wydatku powietrza VAV na nawiewie i wywiewie ze \u015bciennym detektorem obecno\u015bci powoduj\u0105cym otwarcie dop\u0142ywu powietrza. Uk\u0142ad wentylacji zaprojektowano ze zmienn\u0105 wydajno\u015bci\u0105 zale\u017cn\u0105 od jako\u015bci powietrza wewn\u0119trznego, sterowany z systemu automatyki i BMS. Wydajno\u015b\u0107 wentylacji b\u0119dzie obni\u017cana do minimum podczas nieobecno\u015bci u\u017cytkownik\u00f3w obiektu. Wprowadzone rozwi\u0105zania powinny w znacz\u0105cym stopniu wp\u0142yn\u0105\u0107 na obni\u017cenie zu\u017cycia energii przez systemy wentylacji i klimatyzacji.<\/p>\n<a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys6_.jpg\"> <img src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys6_.jpg\" alt=\"Rys. 6. Schemat dwururowej instalacji z wieloma pompami ciep\u0142a (WLHP)\"> <\/a> Rys. 6.<br \/> Schemat dwururowej instalacji z wieloma pompami ciep\u0142a (WLHP)\n<a href=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys7_.jpg\"> <img src=\"https:\/\/informacjainstal.com.pl\/wp-content\/uploads\/2019\/12\/Nowoczesneinstalacjewobiekcieoniskim.rys7_.jpg\" alt=\"Rys.7. Pompa ciep\u0142a przy\u0142\u0105czona do instalacji wodnej przez uk\u0142ad rurowy z zaworem regulacyjnym, filtrem siatkowym i zaworami odcinaj\u0105cymi\"> <\/a> Rys.7.<br \/> Pompa ciep\u0142a przy\u0142\u0105czona do instalacji wodnej przez uk\u0142ad rurowy z zaworem regulacyjnym, filtrem siatkowym i zaworami odcinaj\u0105cymi\n<p style=\"text-align: justify;\">Ogrzewanie i ch\u0142odzenie przestrzeni biurowo-us\u0142ugowej b\u0119dzie realizowane jak wspomniano wcze\u015bniej za pomoc\u0105 urz\u0105dze\u0144 typu pompa ciep\u0142a woda- -powietrze (WLHP) pod\u0142\u0105czonych przewodami do p\u0119tli wodnej dwururowej o zmiennych parametrach pracy dla lata i zimy (rys.6).<\/p> <p style=\"text-align: justify;\">Systemy WLHP (Water Loop Heat Pump) opisywane w literaturze r\u00f3wnie\u017c jako WSHP (Water Source Heat Pump) s\u0105 alternatyw\u0105 dla konwencjonalnych uk\u0142ad\u00f3w klimatyzacyjno \u2013 grzewczych. W ostatnich latach s\u0105 coraz ch\u0119tniej stosowane w obiektach, w kt\u00f3rych wyst\u0119puje r\u00f3\u017cne zapotrzebowanie na energi\u0119 do ch\u0142odzenia i ogrzewania w poszczeg\u00f3lnych obszarach i pomieszczeniach. Wykorzystuj\u0105c uk\u0142ad WLHP mo\u017cna ciep\u0142o lub ch\u0142\u00f3d odbiera\u0107 z pomieszcze\u0144, gdzie jest go w nadmiarze i wykorzystywa\u0107 w innym miejscu. Odwracalny obieg ch\u0142odniczy tych pomp pozwala na utrzymanie wymaganej temperatury w pomieszczeniach lub strefie niezale\u017cnie od tego, czy wymagaj\u0105 one w danym momencie grzania, czy te\u017c ch\u0142odzenia. Dzi\u0119ki temu w tym samym czasie w jednym obiekcie mo\u017cna jedne pomieszczenia ogrzewa\u0107, a inne ch\u0142odzi\u0107 korzystaj\u0105c z jednej instalacji. System WLHP jest uk\u0142adem wielu pomp ciep\u0142a typu woda\/powietrze po\u0142\u0105czonych jedn\u0105 instalacj\u0105 hydrauliczn\u0105. W kompleksie us\u0142ugowym \u201ePosejdon\u201d zamontowano 910 takich pomp pracuj\u0105cych w sze\u015bciu uk\u0142adach. Ka\u017cdy z nich umo\u017cliwia transport ciep\u0142a i ch\u0142odu pomi\u0119dzy powietrzem a wod\u0105 z wykorzystaniem uk\u0142adu spr\u0119\u017carkowego pomp ciep\u0142a. Podczas pracy w trybie ch\u0142odzenia energia pobierana z pomieszczenia przekazywana jest do wody kr\u0105\u017c\u0105cej w p\u0119tli wodnej. Podczas pracy w trybie grzania ciep\u0142o jest pobierane z p\u0119tli wodnej i oddawane do powietrza, kt\u00f3re ogrzewa pomieszczenie. G\u0142\u00f3wn\u0105 cech\u0105 tego systemu jest wytwarzanie ciep\u0142a lub ch\u0142odu bezpo\u015brednio w miejscu, w kt\u00f3rym jest wykorzystywane (czyli jest to system zdecentralizowany), co jest bardzo korzystne w aspekcie efektywno\u015bci energetycznej. Uk\u0142ad natomiast potrzebuje centralnego \u017ar\u00f3d\u0142a ciep\u0142a oraz \u017ar\u00f3d\u0142a ch\u0142odu. W przypadku kompleksu \u201ePosejdon\u201d \u017ar\u00f3d\u0142em ciep\u0142a jest grunt. Ciep\u0142o pobierane za pomoc\u0105 wymiennik\u00f3w gruntowych w wymiennikach glikol\/woda przekazywane jest wodzie kr\u0105\u017c\u0105cej w p\u0119tlach pomp ciep\u0142a. Przy maksymalnym zapotrzebowaniu na ciep\u0142o wymienniki glikol\/woda mog\u0105 by\u0107 wspomagane dodatkowa pomp\u0105 ciep\u0142a. \u0179r\u00f3d\u0142em ch\u0142odu r\u00f3wnie\u017c jest wymiennik gruntowy wspomagany wie\u017cami ch\u0142odniczymi (rys.5).<\/p> <p style=\"text-align: justify;\">Pojedyncze pompy ciep\u0142a posiadaj\u0105 certyfikat wysokiej klasy efektywno\u015bci energetycznej (A+), o wska\u017anikach: COP &gt; 4,1, EER &gt; 5,9, LW max &lt; 37,5 dBA.<\/p> <p style=\"text-align: justify;\">Zadaniem instalacji p\u0119tli wodnej jest dostarczanie, odbieranie oraz akumulacja energii. Kr\u0105\u017c\u0105ca woda pe\u0142ni funkcj\u0119 czynnika transportuj\u0105cego energi\u0119 pomi\u0119dzy pomieszczeniami lub ich strefami. W zale\u017cno\u015bci od trybu pracy jest dolnym lub g\u00f3rnym \u017ar\u00f3d\u0142em ciep\u0142a dla zainstalowanych pomp ciep\u0142a. Jednocze\u015bnie pe\u0142ni ona funkcj\u0119 akumulatora energii, kt\u00f3ra swobodnie mo\u017ce zosta\u0107 wykorzystana przez ka\u017cd\u0105 z pomp ciep\u0142a znajduj\u0105c\u0105 si\u0119 w p\u0119tli. Gdy temperatura wody w p\u0119tli mie\u015bci si\u0119 w granicach od 14 do 25 \u00b0C uk\u0142ad znajduje si\u0119 w r\u00f3wnowadze termodynamicznej. Oznacza to, \u017ce pompy ciep\u0142a w budynku mog\u0105 pracowa\u0107 r\u00f3wnocze\u015bnie w trybie ch\u0142odzenia jak i grzania (w zale\u017cno\u015bci od potrzeb indywidualnych pomieszcze\u0144) bez konieczno\u015bci dostarczania lub odbierania energii z centralnego \u017ar\u00f3d\u0142a ciep\u0142a lub ch\u0142odu (wymiennika gruntowego). Wp\u0142ywa to na obni\u017cenie koszt\u00f3w eksploatacyjnych systemu grzewczo- ch\u0142odz\u0105cego w obiekcie.<\/p> <p style=\"text-align: justify;\">Ka\u017cda z 910 pomp ciep\u0142a b\u0119dzie pod\u0142\u0105czona do instalacji przez uk\u0142ad rurowy z zaworem regulacyjnym, filtrem siatkowym i zaworami odcinaj\u0105cymi (rys. 7). Ze wzgl\u0119du na zmienne zapotrzebowanie na ch\u0142\u00f3d i ciep\u0142o obs\u0142ugiwanych przez p\u0119tl\u0119 wodn\u0105 pomieszcze\u0144 istotne jest zastosowanie bardzo precyzyjnej regulacji przep\u0142ywu. Jako\u015b\u0107 tej regulacji jest bardzo istotna z uwagi zar\u00f3wno na dotrzymanie za\u0142o\u017conych temperatur w pomieszczeniach, jak i w kontek\u015bcie minimalizacji zu\u017cycia energii elektrycznej do nap\u0119du pomp wymuszaj\u0105cych obieg czynnika w pier\u015bcieniu wodnym. Z tego powodu jako zawory regulacyjne zastosowano nowoczesne zawory r\u00f3wnowa\u017c\u0105ce ABQM z nap\u0119dem cyfrowym NovoCon\u00ae firmy Danfoss, dzi\u0119ki kt\u00f3rym uk\u0142ad b\u0119dzie w stanie zapewni\u0107 uzyskanie komfortu cieplnego w pomieszczeniach, znacz\u0105cych oszcz\u0119dno\u015bci energii i co ma ogromne znaczenie dla sprawnej eksploatacji zapewniaj\u0105c bardziej precyzyjn\u0105 wsp\u00f3\u0142prac\u0119 armatury regulacyjno- -r\u00f3wnowa\u017c\u0105cej z systemem BMS. Zastosowane urz\u0105dzenia umo\u017cliwi\u0105 znaczn\u0105 oszcz\u0119dno\u015b\u0107 czasu podczas monta\u017cu, zdalne uruchomienie systemu i wykonanie nastawy na zaworze. Pozwol\u0105 tak\u017ce wykry\u0107 potencjalne nieprawid\u0142owo\u015bci pracy uk\u0142adu lub b\u0142\u0119dy monta\u017cowe oraz wystarczaj\u0105co precyzyjnie okre\u015bli\u0107 indywidualne zu\u017cycie ciep\u0142a lub ch\u0142odu w obs\u0142ugiwanych pomieszczeniach (rejestr i alokacja zu\u017cycia energii).<\/p> <p style=\"text-align: justify;\">Zaw\u00f3r ABQM jest zaworem regulacyjnym z wbudowanym regulatorem ci\u015bnienia, kt\u00f3ry utrzymuje sta\u0142y spadek ci\u015bnienia w cz\u0119\u015bci regulacyjnej. Ten sta\u0142y spadek ci\u015bnienia jest niezale\u017cny od waha\u0144 ci\u015bnienia w instalacji (b\u0119d\u0105cych konsekwencj\u0105 zmiennych przep\u0142yw\u00f3w), co zabezpiecza instalacj\u0119 przed zjawiskiem tzw. nadprzep\u0142yw\u00f3w oraz pozwala na utrzymanie niezmiennej charakterystyki zaworu regulacyjnego. Ma to bezpo\u015bredni wp\u0142yw na utrzymanie wysokiego komfortu cieplnego w pomieszczeniach przy jednoczesnym zapewnieniu optymalnego przep\u0142ywu czynnika. Konstrukcja zaworu jest tak zaprojektowana, i\u017c dla poprawnej pracy zaworu wystarczy zapewnienie minimalnego spadku ci\u015bnienia na zaworze na poziomie 16 kPa, co ma bezpo\u015bredni wp\u0142yw na dob\u00f3r pomp w uk\u0142adach hydraulicznych \u2013 wp\u0142ywa na obni\u017cenie koszt\u00f3w eksploatacyjnych wynikaj\u0105cych z koszt\u00f3w pompowania.<\/p> <p style=\"text-align: justify;\">Dzi\u0119ki wsp\u00f3\u0142pracy zaworu z si\u0142ownikiem NovoCon mo\u017ce on by\u0107 wykorzystywany w systemach BMS (Building Management System). Ten krokowo-cyfrowy nap\u0119d posiada cztery grupy funkcji, kt\u00f3re powoduj\u0105, i\u017c jest to obecnie unikalne rozwi\u0105zanie dedykowane instalacji HVAC:<\/p> <p style=\"text-align: justify;\">\u2013 funkcja komunikacji \u2013 umo\u017cliwia wpi\u0119cie 64 nap\u0119d\u00f3w do jednego obwodu, dokonywanie zdalnych nastaw (obliczeniowych przep\u0142yw\u00f3w ich ewentualnych zmian, wywo\u0142ania funkcji p\u0142ukania czy odpowietrzania, rozpoznanie stan\u00f3w awaryjnych i ich przyczyny), monitoring, analiz\u0119 i diagnostyk\u0119 pracy uk\u0142adu. Funkcja ta ma bezpo\u015bredni wp\u0142yw na koszty uruchamiania oraz eksploatacji instalacji;<\/p> <p style=\"text-align: justify;\">\u2013 funkcja modu\u0142\u00f3w wej\u015bcia\/wyj\u015bcia (Input\/Output) \u2013 umo\u017cliwia wsp\u00f3\u0142prac\u0119 zaworu z wieloma obiektami, jak: czujniki ruchu, otwarcia okna, temperatur, wilgotno\u015bci, zanieczyszczenia, itd. Modu\u0142y te mog\u0105 by\u0107 bezpo\u015brednio wpi\u0119te do nap\u0119du bez konieczno\u015bci zastosowania dodatkowych sterownik\u00f3w czy przeka\u017anik\u00f3w. Umo\u017cliwia to zapewnienie optymalnej pracy uk\u0142adu przy jednoczesnym maksymalnym komforcie ciep\u0142ym u\u017cytkownika oraz ci\u0105g\u0142y monitoring parametr\u00f3w pompy ciep\u0142a;<\/p> <p style=\"text-align: justify;\">\u2013 funkcja zarz\u0105dzania energi\u0105 (Energy Management) \u2013 umo\u017cliwia monitoring i kontrol\u0119 minimalnej r\u00f3\u017cnicy temperatur na odbiorniku, nastaw\u0119 i kontrol\u0119 r\u00f3\u017cnicy temperatur oraz temperatury powrotu, ograniczenie minimalnej temperatury powrotu, ograniczenie maksymalnej temperatury powrotu. Funkcja ta zapewnia poprawn\u0105 prac\u0119 uk\u0142ad\u00f3w grzania i ch\u0142odzenia dzi\u0119ki mo\u017cliwo\u015bci utrzymania warunk\u00f3w obliczeniowych dla ka\u017cdych warunk\u00f3w pracy instalacji;<\/p> <p style=\"text-align: justify;\">\u2013 funkcja alokacji energii \u2013 umo\u017cliwia wykorzystanie wbudowanych zaawansowanych funkcji pomiaru zu\u017cycia energii przez pompy ciep\u0142a oraz jej kontroli. Rozwi\u0105zanie to obecnie jest stosowane jako mo\u017cliwo\u015bci alokacji energii wed\u0142ug faktycznego zu\u017cycia a nie wed\u0142ug metr\u00f3w kwadratowych zajmowanej powierzchni. Funkcja ta mo\u017ce by\u0107 wykorzystywana do analizy systemu, obci\u0105\u017cenia, efektywno\u015bci, sprawno\u015bci oraz natychmiastowej interwencji w przypadkach marnowania energii czy te\u017c jej zu\u017cycia w miejscach, gdzie nikt z tego nie korzysta.<\/p> <p style=\"text-align: justify;\">Standard instalacji HVAC w obiekcie \u201ePosejdon\u201d daleko wykracza poza obowi\u0105zuj\u0105ce obecnie normy. Zastosowane technologie pozwoli\u0142y na uzyskanie presti\u017cowego certyfikatu ekologicznego BREEAM w najnowszej wersji New Construction 2016 na poziomie EXCELLENT. Ocena w ramach certyfikacji BREEAM odbywa si\u0119 w dziesi\u0119ciu kategoriach: Zarz\u0105dzanie, Zdrowie i dobre samopoczucie, Energia, Transport, Woda, Materia\u0142y, Odpady, Wykorzystanie terenu i ekologia, Zanieczyszczenia oraz Innowacje. Aby m\u00f3c ubiega\u0107 si\u0119 o certyfikat w ka\u017cdej z tych kategorii trzeba zdoby\u0107 okre\u015blon\u0105 liczb\u0119 punkt\u00f3w krytycznych. Istnieje te\u017c obszerna lista dodatkowych wymaga\u0144, za spe\u0142nienie kt\u00f3rych otrzymuje si\u0119 kolejne punkty. Ich suma decyduje o przyznaniu certyfikatu w pi\u0119ciostopniowej skali. Poziom EXCELLENT jest stopniem czwartym, kt\u00f3ry potwierdza, \u017ce obiekt spe\u0142ni\u0142 ponad 70 procent wy\u015brubowanych wytycznych brytyjskiej organizacji certyfikuj\u0105cej. Certyfikat BREEAM potwierdza, \u017ce dzi\u0119ki zastosowaniu wielu rozwi\u0105za\u0144 redukuj\u0105cych zu\u017cycie energii budynek jest proekologiczny i oszcz\u0119dny dla jego w\u0142a\u015bciciela oraz i\u017c zosta\u0142 wykonany wg najnowszych, europejskich norm i standard\u00f3w, dzi\u0119ki czemu zapewnia najwy\u017cszy komfort jego u\u017cytkownikom.<\/p>\n<p><strong>System BMS w \u201ePosejdonie\u201d<\/strong><\/p> <p style=\"text-align: justify;\">Obiekt \u201ePosejdon\u201d zawiera pomieszczenia o r\u00f3\u017cnym charakterze (m.in. hotelowe, biurowe, sale konferencyjne, lokale handlowo-us\u0142ugowe, serwerownie, maszynownie, gara\u017ce), kt\u00f3re wymagaj\u0105 odr\u0119bnego systemu gwarantuj\u0105cego zr\u00f3\u017cnicowany poziom komfortu i bezpiecze\u0144stwa. Aby wszystkie te elementy stanowi\u0142y sp\u00f3jn\u0105 i dobrze funkcjonuj\u0105c\u0105 ca\u0142o\u015b\u0107, w obiekcie funkcjonowa\u0107 b\u0119dzie zaawansowany system automatycznej regulacji i sterowania \u2013 BMS (Building Management System) uzupe\u0142niony o funkcjonalno\u015bci pozwalaj\u0105ce na zarz\u0105dzanie zu\u017cyciem energii. System zapewni w\u0142a\u015bciwe parametry \u015brodowiska wewn\u0119trznego (komfortu u\u017cytkownik\u00f3w) przy racjonalnym zu\u017cyciu energii. B\u0119dzie \u017ar\u00f3d\u0142em informacji, analiz i wytycznych umo\u017cliwiaj\u0105cych kompleksowe spojrzenie na zu\u017cycie energii w obiekcie. W postaci interaktywnych grafik umo\u017cliwi wizualizacj\u0119 zu\u017cycia energii i zarz\u0105dzanie energi\u0105 oraz jej alokacj\u0119, pozwoli na por\u00f3wnanie zu\u017cycia energii w stosunku do poprzednich okres\u00f3w rozliczeniowych, wprowadzanie plan\u00f3w energetycznych, ci\u0105g\u0142e optymalizowanie zu\u017cycia energii, popraw\u0119 efektywno\u015bci energetycznej i wska\u017anik\u00f3w eksploatacyjnych przez ca\u0142y okres u\u017cytkowania budynku. Dzi\u0119ki temu mo\u017cna b\u0119dzie podejmowa\u0107 trafne decyzje przyczyniaj\u0105ce si\u0119 do zminimalizowania zu\u017cycia energii w budynku. W zwi\u0105zku z tym, \u017ce najwi\u0119ksze zapotrzebowanie na energi\u0119 jest zwi\u0105zane z o\u015bwietleniem, ogrzewaniem i klimatyzacj\u0105 zastosowane zosta\u0142y, szczeg\u00f3lnie w tych instalacjach, nowoczesne rozwi\u0105zania wspieraj\u0105ce popraw\u0119 efektywno\u015bci energetycznej. Uk\u0142ady wentylacji zaprojektowano ze zmienn\u0105 wydajno\u015bci\u0105 zale\u017cn\u0105 od jako\u015bci powietrza wewn\u0119trznego. Wydajno\u015b\u0107 wentylacji b\u0119dzie obni\u017cana do minimum podczas nieobecno\u015bci u\u017cytkownik\u00f3w obiektu. Optymalna temperatura wewn\u0119trzna b\u0119dzie kontrolowana za pomoc\u0105 odpowiedniego zag\u0119szczenia czujnik\u00f3w temperatury z mo\u017cliwo\u015bci\u0105 regulacji temperatury odr\u0119bnie w poszczeg\u00f3lnych pomieszczeniach. Dodatkowo zastosowano monitorowanie otwarcia okien przez u\u017cytkownik\u00f3w. W takim przypadku wy\u0142\u0105czane s\u0105 \u017ar\u00f3d\u0142a ciep\u0142a\/ch\u0142odu (pompy ciep\u0142a) na danej powierzchni lub w pomieszczeniu. U\u017cytkownicy obiektu b\u0119d\u0105 mogli samodzielnie kontrolowa\u0107 o\u015bwietlenie oraz temperatur\u0119 za pomoc\u0105 zadajnik\u00f3w w pomieszczeniach.<\/p> <p style=\"text-align: justify;\">Szczeg\u00f3\u0142owo opomiarowane zostanie w budynku m.in.:<\/p> <p style=\"text-align: justify;\">\u2013\u2013 zu\u017cycie wody,<\/p> <p style=\"text-align: justify;\">\u2013\u2013 zu\u017cycie energii elektrycznej,<\/p> <p style=\"text-align: justify;\">\u2013\u2013 zu\u017cycie ciep\u0142a i ch\u0142odu<\/p>\n<p><strong>Podsumowanie<\/strong><\/p> <p style=\"text-align: justify;\">W artykule skoncentrowano si\u0119 na nowoczesnych technologiach z u\u017cyciem energii odnawialnej wdro\u017conych w kompleksie us\u0142ugowym \u201ePosejdon\u201d. Ten najwi\u0119kszy w Polsce NZEB mo\u017cna traktowa\u0107 jako obiekt referencyjny. Jest on wyposa\u017cony mi\u0119dzy innymi w systemy fotowoltaiczne, w uk\u0142ad pozyskiwania energii dla potrzeb grzania i ch\u0142odzenia zrealizowany w oparciu o pionowe wymienniki gruntowe i wykorzystanie pomp ciep\u0142a pracuj\u0105cych w uk\u0142adzie hydraulicznym p\u0119tli wodnej (WLHP). Budynek zosta\u0142 zaprojektowany tak, aby s\u0142u\u017cy\u0142 tak\u017ce jako laboratorium do badania mo\u017cliwo\u015bci zastosowania zaimplementowanych w nim innowacyjnych strategii s\u0142u\u017c\u0105cych wysokiej efektywno\u015bci energetycznej i zmniejszeniu emisji gaz\u00f3w cieplarnianych. Rozwi\u0105zania przedstawione w artykule mo\u017cna traktowa\u0107 jako zbi\u00f3r dobrych praktyk w zakresie realizacji budynk\u00f3w w standardzie NZEB.<\/p>\n<p><strong>BIBLIOGRAFIA<\/strong><\/p> <p style=\"text-align: justify;\">[1] COM (2011) 112 final, The Committee report for the EP and the Council, the European Economic and Social Committee and the Committee of the Regions \u2013 A Roadmap for moving to a competitive low carbon economy in 2050. Pobrane z adresu: https:\/\/eur-lex.europa.eu\/ LexUriServ\/LexUriServ.do?uri=COM:2011:0112:FIN:EN:PDF<\/p> <p style=\"text-align: justify;\">[2] COM (2013) 483 final\/2. The Committee report for the EP and the Council \u2013 The progress of member countries in increasing the number of buildings with nearly zero energy use, 7.10.2013 r. Pobrane z adresu: https:\/\/ ec.europa.eu\/energy\/en\/topics\/energy \u2013 efficiency\/buildings<\/p> <p style=\"text-align: justify;\">[3] EPBD (2002). Directive 2002\/91\/WE of the European Parliament and of the Council of 16 December 2002 on the energy performance of buildings. OJ L 1\/65 04.01.2003.<\/p> <p style=\"text-align: justify;\">[4] EPBD (2010). Directive 2010\/31\/UE of the European Parliament and the Council of 19 Mai 2010 on the energy performance of buildings (recast). OJ L 153 18.06.2010.<\/p> <p style=\"text-align: justify;\">[5] EPBD (2018). Directive (EU) 2018\/844 of the European Parliament and of the council of 30 May 2018 amending Directive 2010\/31\/EU on the energy performance of buildings and Directive 2012\/27\/EU on energy efficiency. Off. J. Eur. Union 2018, 156, 75\u201391.<\/p> <p style=\"text-align: justify;\">[6] Obwieszczenie Ministra Infrastruktury i Rozwoju z dnia 17 lipca 2015 r. w sprawie og\u0142oszenia jednolitego tekstu rozporz\u0105dzenia Ministra Infrastruktury w sprawie warunk\u00f3w technicznych, jakim powinny odpowiada\u0107 budynki i ich usytuowanie. Za\u0142\u0105cznik 2. Wymagania izolacyjno\u015bci cieplnej i inne wymagania zwi\u0105zane z oszcz\u0119dno\u015bci\u0105 energii<\/p> <p style=\"text-align: justify;\">[7] Rozporz\u0105dzenie Ministra Infrastruktury z dnia 12 kwietnia 2002 r. w sprawie warunk\u00f3w technicznych, jakim powinny odpowiada\u0107 budynki i ich usytuowanie. Dz.U. 2002 Nr 75, poz. 690<\/p> <p style=\"text-align: justify;\">[8] Pirczewski M., Figiel E., Leciej-Pirczewska D.: \u201eNowoczesny kompleks us\u0142ugowy POSEJDON w Szczecinie\u201d. In\u017cynieria i Budownictwo, 5\/20<\/p>","_links":{"self":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul\/6547","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/artykul"}],"about":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/types\/artykul"}],"wp:attachment":[{"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/media?parent=6547"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tags?post=6547"},{"taxonomy":"tematyka","embeddable":true,"href":"https:\/\/informacjainstal.com.pl\/en\/wp-json\/wp\/v2\/tematyka?post=6547"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}