The significance of odour concentration measurement uncertainty in the acceptance process of a odour removal installation
author:
MAŁGORZATA LATZKE
ORCID ID:
0000-0002-6457-253X
No:
12/2025 Instal pp.125-130
DOI:
10.36119/15.2025.12.23
A reliable assessment of the effectiveness of odour removal installations is crucial for protecting air quality and
reducing odour nuisance. This article analyses the impact of measurement uncertainty on the assessment of the
acceptance of installations, taking into account the number of control measurements and the selection of
a representative emission value. It was shown that the use of average emission values can lead to an underestimation
of the impact, while the use of the upper limit of the 95% confidence interval increases the predicted nuisance range
by 80-160 m. It was also pointed out, that there are situations in which the choice of representative value does not
affect the assessment. The results emphasize the importance of taking measurement uncertainty into account in the
acceptance process of a odour removal installation.
Keywords:
About Authors:
dr inż. Małgorzata Latzke https://orcid.org/0000-0002-6457-253X ‒ Zachodniopomorski Uniwersytet Technologiczny w Szczecinie, Wydział Technologii i Inżynierii Chemicznej, Laboratorium Zapachowej Jakości Powietrza.