Protective properties of a multi-layer external coating applied to underground pipes of ductile iron
author:
AGNIESZKA KOCHMAŃSKA, ANNA WASSILKOWSKA, WOJCIECH DĄBROWSKI
ORCID ID:
0000-0001-5502-2838, 0000-0003-0896-793X
No:
8/2020 Instal p. 29-32
DOI:
10.36119/15.2020.8.5
In this work the analysis of corrosion for ductile iron pipes with diameters of 350 and 500 mm was performed. Two
phenomena regarding the pipes coating deterioration have been recognized: corrosion and abrasion. The
corrosion tests performed on different coatings in a neutral salt spray for up to 1000 hours indicate that this method
is applicable for a rough external surface of centrifugally casted ductile iron pipes. The abrasion tests have been
performed manually, using a grinding paper 1000#, due to an irregular profile of the external pipe surface
transferred from the casting mold. It helped to obtain “spotted” sections, which were further microscopically
analyzed (layer-by-layer). The last procedure, however not standardized, could be in some regards more convenient
comparing to traditional cross-sections.
Keywords:
About Authors:
dr hab. inż. Agnieszka Kochmańska, https://orcid.org/0000-0001-5502-2838 – West Pomeranian University of Technology, Szczecin, Poland;
dr hab. inż. Anna Wassilkowska, https://orcid.org/0000-0003-0453-3480; prof. dr hab. inż. Wojciech Dąbrowski, https://orcid.org/
0000-0003-0896-793X – Cracow University of Technology, Cracow, Poland. Corresponding author: wdabrow@pk.edu.pl