Verification of the selection of the diameter of the steam condenser tube for a 200 MW unit
author:
RAFAŁ LASKOWSKI, ADAM SMYK, ARTUR RUSOWICZ, ANDRZEJ GRZEBIELEC, ADAM RUCIŃSKI
ORCID ID:
0000-0002-0248-7866, 0000-0002- 9514-7907, 0000-0001-7949-6907, 0000-0003-3320-5929, 0000-0001-6545-9865
No:
02/2022 Instal p. 11-15
DOI:
10.36119/15.2022.2.2
In steam power plants condensers, the condensation heat of the steam is removed to the environment. The geometry (heat transfer surface area, tube diameter) and the operating conditions of the steam condensers influence the power
plant performance (power and efficiency). As the diameter of the steam condenser tube changes, the heat transfer
conditions and the cooling water flow resistance change, which translates into the pressure of condensing steam, the power generated by the turbine, the power needed to drive the cooling water pump and the power plant efficiency. Due to the extension of the operating time of 200 MW class power units and their greater flexibility of operation in
the power system, the article verifies the selection of the diameter of the steam condenser tube in order to investigate
the possibilities of improving performance. The 200 MW unit model was created in the Ebsilon program. The optimization criterion is to maximize the power and net efficiency of the unit.
Keywords:
About Authors:
dr hab. inż. Rafał Laskowski, Profesor PW https://orcid.org/0000-0002-0248-7866, dr inż. Adam Smyk https://orcid.org/0000-0002-9514-7907, dr hab. inż Artur Rusowicz, Profesor PW https://orcid.org/0000-0001-7949-6907, dr inż. Andrzej Grzebielec https://orcid.org/0000-0003-3320-5929, dr inż. Adam Ruciński htps://orcid.org/0000-0001-6545-9865 – Instytut Techniki Cieplnej, Wydział Mechaniczny Energetyki i Lotnictwa, Politechnika Warszawska, Warszawa.